background image

 

5/8 

 

8.

b

 

  

 

Launch a setup (to take a reference picture)

 

 

Unlock

 the sensor to enter into adjustment 

session 

 

 

RED LED 

Press Unlock key 

flashes slowly 

 

To launch an assisted setup 

Æ

  recommended after mechanical 

adjustments of the IR sensor module. 

Æ

  recommended once after the first 

installation 

 

 

 

 Press Setup key followed 

by 0 

RED/GREEN LED 

alternating 

The sensor performs a door opening and closing cycle to check  
the influence of the door leaves to the safety curtains.  
See Troubleshooting if RED LED flashes quickly after setup.  

 

To launch a setup 

Æ

  recommended after change of 

parameters by remote control 

 

 

 

 Press Setup key twice 

 

RED/GREEN LED 

alternating

 

The sensor only takes a new reference picture.  

 

 

LED display during sensor assisted setup 

 

 

RED/GREEN  

LED 

alternating

 

Setup-process active: the sensor learns its environment. 
After finishing the setup process, the sensor shows the following behavior: 

 

RED LED flashing quickly 

The sensor ‘sees’ the door movement and can not finish its setup. 

 

 

 

 

RED LED continuously on 

The sensor signals a faulty IR monitoring. 

 

 

 

 

ORANGE LED continuously on 

The sensor encounters a signal saturation  
(ex. due to a highly reflective floor). 

 

 

 

 

No LED turns on 

The sensor successfully finished its setup. 

 

 
 

 

 

 

 

 

 

 
 

 

 

 

 

 

 

 
 

 

 

 

 

8.

c

 

  

 

Additional Remote Control adjustments

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Hold time

 

 

 

 

0

 (0.5s)

 

 

9

 (9s)

 

 

Detection mode      

 

 

 

1

 bidirectional 

mode 

2

 unidirectional mode 

3

 

unidirectional mode with MTF

 

 

External 

Monitoring Enable 

 

 

monitoring disabled (OFF) 

1

 monitoring enabled (ON)

 

 

Safety output 

redirection 

F1

 

 

 

0

 no redirection 

1

 

transfer presence detection to  

 motion 

output 

2

 

motion output activated if motion  

 and 

presence 

detection

 

 

Installation 

Configuration 

 

 

 

 

 

 

Mounting  

Height 

Pulse 

Frequency 

1

 

Low 

Low 

High 

Low 

Low 

High 

High 

High 

 

Immunity           

 

 

 

1

 sismo 

 

2

   normal  

3

   Increased

 

Summary of Contents for BEA ACTIV8 THREE ON

Page 1: ...otion detection RED LED Presence detection Short flash after a motion or presence detection Monitoring process active ORANGE LED See chapter 5 Troubleshooting 1 Tips Use the Remote Control to adjust the sensor Use the Spotfinder to locate the safety curtains Avoid touching electronical parts Avoid touching optical parts Make sure the operator cover is fixed properly and electrically earthed Avoid ...

Page 2: ...n above 4 Radar motion sensing field width Sensitivity 9 Sensitivity 9 5 Radar motion sensing field depth 15 30 45 30 45 15 0 2 1 0 1 2 1 2 3 1 2 3 15 30 45 Sensitivity 9 2 1 0 1 2 1 2 3 1 2 3 15 45 30 4 4 Sensitivity 9 SENSOR DOOR CONTROLLER 12 24V AC DC Monitoring Input Monitoring Output Beam transmitter Safety Input Beam receiver keep door open Monitored Impulse Input open door Sensor Power Sup...

Page 3: ...rew clockwise To tilt the curtain out turn the screw counterclockwise min 5cm min 5cm 0 4 Keep a minimum distance of 5cm Å between the door and the first curtain Use the Spotfinder accessory to locate and adjust the position of the curtains When mounting one sensor on each side of the door above a highly reflective threshold select different frequencies to avoid crosstalk between the sensors see s...

Page 4: ...Select parameter to check flashes quickly Press Question Mark The number of green flashes indicate the value of this parameter flashes slowly Lock the adjustment session and go back to normal function Press Lock key twice 8 a Important Remote Control adjustments Sensitivity 0 min 9 max Factory value 7 IR curtain immunity 1 normal 2 increased 3 rain mode 4 snow mode 5 snow mode enhanced Output conf...

Page 5: ...process active the sensor learns its environment After finishing the setup process the sensor shows the following behavior RED LED flashing quickly The sensor sees the door movement and can not finish its setup RED LED continuously on The sensor signals a faulty IR monitoring ORANGE LED continuously on The sensor encounters a signal saturation ex due to a highly reflective floor No LED turns on Th...

Page 6: ...ommended to set sensors close to each other with remote control The access code can be composed of 1 to 4 digits factory values or no access code 0 or 0000 No code is required to unlock during the first minute after powering Overlapping IR curtains Overlapping IR curtains from sensors installed side by side may cause disturbances due to crosstalk interferences Select different frequencies on each ...

Page 7: ...le turning the screw counterclockwise The door is not closing LED OFF On Off switch at door control is in wrong position or is faulty Check to insure that On Off switch for door is in the ON or AUTOMATIC position Improper output configuration on the sensor Check the output configuration setting on each sensor Faulty sensor monitoring of the door controller Check if the monitoring mode is ON or PUL...

Page 8: ...essor Spot diameter standard 0 1m max Number of spots 24 or 12 spots by curtain Number of curtains 2 Detection field Width Depth Wide 4 m 2 m Narrow 2 m 2 5 m Width Depth Wide 2 m 0 35 m Narrow 1 m 0 35 m Angle From 15 to 50 in elevation adjustable From 4 to 4 adjustable Output specification Free of potential current source State No detection current source ON Max open circuit voltage 6 5V Output ...

Reviews: