4/8 

 

 

  

 

Remote Control adjustments (only when factory settings do not match)

 

 

 

Unlock

 the sensor to enter into adjustment 

session (if no access code has been 
entered) 

 

 

RED LED 

Press Unlock key 

flashes slowly 

 

 

To change the value of a parameter  
(ex. Maximum duration of presence 
detection) 

 

 

 

 

 

RED LED 

RED LED 

 

Select parameter 

to change 

flashes quickly   

Enter new value 

flashes slowly 

 

 

 

… to change any other parameters  
(ex. Output Configuration) 

 

 

 

 

 

RED LED 

RED LED 

 

Select parameter 

to change 

flashes quickly   

Enter new value 

flashes slowly 

 

 

 

To check the value of a parameter (ex. 
maximum duration of presence detection) 

 

 

 

 

 

 

 

… 

 

RED LED 

GREEN 

GREEN 

GREEN 

GREEN 

 

RED LED 

Select parameter 

to check 

flashes quickly   

Press Question 

Mark 

The number of green flashes indicate the value of this parameter 

flashes slowly  

 

Lock

 the adjustment session and go back to 

normal function 

 

 

Press Lock key twice 

 

 

 

 

 

 
 

 
 
 

 

8.

a

 

  

 

Important Remote Control adjustments

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Sensitivity 

 

 

 

0

 (min) 

 

9

 (max) 

Factory value : 7 

 

 

 

IR curtain 

 immunity 

 

 

 

1

 normal 

2  

increased

 

3

 rain-mode 

4

 snow-mode 

 

snow-mode enhanced 

 

Output configuration  

 

 

 

Motion-Out 

Presence-Out 

1

 

Active 

Passive 

2

 

Passive 

Active 

3

 

Passive 

Passive 

4

 

Active 

Active 

 

 

Number of IR 

curtains         

 

 

 

1

 1 

curtain 

  (safety curtain close to the door) 

2

 

 

2 curtains

 

3

 

2

nd

 curtain in dynamic mode

 

Unlock 

 

Check values 

Lock 

 

Setup     

 
 

 

   launch a setup

 

 

 

 

launch an assisted setup 

 

 

   restore factory settings 

 

 

Max. duration of 

presence detection  

 

 

 

0

 30 

seconds 

1

 1 

minute 

2

 

2  minutes  

3

 5 

minutes 

4

 10 

minutes 

5

 20 

minutes 

6

 60 

minutes 

Summary of Contents for BEA ACTIV8 THREE ON

Page 1: ...otion detection RED LED Presence detection Short flash after a motion or presence detection Monitoring process active ORANGE LED See chapter 5 Troubleshooting 1 Tips Use the Remote Control to adjust the sensor Use the Spotfinder to locate the safety curtains Avoid touching electronical parts Avoid touching optical parts Make sure the operator cover is fixed properly and electrically earthed Avoid ...

Page 2: ...n above 4 Radar motion sensing field width Sensitivity 9 Sensitivity 9 5 Radar motion sensing field depth 15 30 45 30 45 15 0 2 1 0 1 2 1 2 3 1 2 3 15 30 45 Sensitivity 9 2 1 0 1 2 1 2 3 1 2 3 15 45 30 4 4 Sensitivity 9 SENSOR DOOR CONTROLLER 12 24V AC DC Monitoring Input Monitoring Output Beam transmitter Safety Input Beam receiver keep door open Monitored Impulse Input open door Sensor Power Sup...

Page 3: ...rew clockwise To tilt the curtain out turn the screw counterclockwise min 5cm min 5cm 0 4 Keep a minimum distance of 5cm Å between the door and the first curtain Use the Spotfinder accessory to locate and adjust the position of the curtains When mounting one sensor on each side of the door above a highly reflective threshold select different frequencies to avoid crosstalk between the sensors see s...

Page 4: ...Select parameter to check flashes quickly Press Question Mark The number of green flashes indicate the value of this parameter flashes slowly Lock the adjustment session and go back to normal function Press Lock key twice 8 a Important Remote Control adjustments Sensitivity 0 min 9 max Factory value 7 IR curtain immunity 1 normal 2 increased 3 rain mode 4 snow mode 5 snow mode enhanced Output conf...

Page 5: ...process active the sensor learns its environment After finishing the setup process the sensor shows the following behavior RED LED flashing quickly The sensor sees the door movement and can not finish its setup RED LED continuously on The sensor signals a faulty IR monitoring ORANGE LED continuously on The sensor encounters a signal saturation ex due to a highly reflective floor No LED turns on Th...

Page 6: ...ommended to set sensors close to each other with remote control The access code can be composed of 1 to 4 digits factory values or no access code 0 or 0000 No code is required to unlock during the first minute after powering Overlapping IR curtains Overlapping IR curtains from sensors installed side by side may cause disturbances due to crosstalk interferences Select different frequencies on each ...

Page 7: ...le turning the screw counterclockwise The door is not closing LED OFF On Off switch at door control is in wrong position or is faulty Check to insure that On Off switch for door is in the ON or AUTOMATIC position Improper output configuration on the sensor Check the output configuration setting on each sensor Faulty sensor monitoring of the door controller Check if the monitoring mode is ON or PUL...

Page 8: ...essor Spot diameter standard 0 1m max Number of spots 24 or 12 spots by curtain Number of curtains 2 Detection field Width Depth Wide 4 m 2 m Narrow 2 m 2 5 m Width Depth Wide 2 m 0 35 m Narrow 1 m 0 35 m Angle From 15 to 50 in elevation adjustable From 4 to 4 adjustable Output specification Free of potential current source State No detection current source ON Max open circuit voltage 6 5V Output ...

Reviews: