background image

 

HALLMARK INDUSTRIES INC 

Shallow Well Jet  Pumps

 

624 Estes Ave, Schaumburg, IL 60193, USA             

www.hallmarkind.com

 

 

Installation

 

4.

 

Install a priming tee, priming plug, and suction pipe to the pump

 

(see Figure  2). Connect the pipe from the well  to the pump suction 
port, using the fewest possible fittings 

– especially elbows – as fittings 

increase friction  in the pipe (however, include a foot valve 

– see 

Figure 2). The suction pipe should be at least  as large as the suction 
port on the pump. Support the pipe so that there are no dips or sags

 

in the pipe, so it  doesn

’t strain the pump body, and so that it slopes 

slightly upward from the well  to the pump (high spots can cause air 
pockets which  can air lock the pump). Seal the pipe joints with T

eflon™ 

tape or a T

eflon™ based pipe joint  compound. Joints must be air- and 

water-tight. If the suction pipe can suck air, the pump cannot pull  water 
from the well.

 

To Household

 

Water System

 

Pump Priming 
Tee with Plug 
or Gauge

 

Suction Pipe

 

From Well

 

You have just completed the suction piping for your new shallow well  jet

 

pump. Please go to Page 4 for discharge pipe and tank connections.

 

Installation for  Surface Water 

(Figure 3)

 

Possible  contamination.  

Do not use surface  water for drinking.

 

The installation shown could be used for sprinkler applications.

 

1.

 

The pump should be installed as close to the water as possible,  with

 

the fewest possible fittings (especially elbows) in the suction pipe. The 
suction pipe should be at least  as large as the suction port on the pump. 
Assemble a foot valve and suction pipe (see Figure  3). Make sure that

 

the foot valve works freely. Use T

eflon™ tape or a Teflon™-based

 

pipe joint  compound on threaded pipe joints. Protect the foot valve 
assembly from fish, trash, etc, by installing a screen around it (see 
Figure 3).

 

Lower the pipe into the water until  the strainer is five feet above the 
bottom. It should also be at least 10 feet below  the water level in order 
to prevent the pump from sucking air.

 

Install a priming tee, priming plug, and suction pipe to the pump (see 
Figure 3). Support the pipe so that there are no dips or sags in the pipe, 
so it doesn

’t strain the pump body, and so that it slopes slightly upward 

from the well  to the pump (high spots can cause air pockets which  can 
air lock the pump). Seal the pipe joints with T

eflon™ tape or a Teflon™ 

based pipe joint  compound. Joints must be air- and water-tight. If the 
suction pipe can suck air, the pump cannot pull  water from the well.

 

10' 

Min.

 

Foot

 

2.

 

5

–10'

 

Figure 3: Surface Water Installation

 

3.

 

4.

 

You have just completed the plumbing for your new shallow well  jet pump.

 

Please go to Page  4 for discharge pipe and tank connections.

 

Valve

 

     

Screen

 

 

     

 

 

 

 

 

 

 

 

 

 

Model 

HP 

Intake 

(NPT) 

Discharge 

(NPT) 

Max 
flow  

Max head 

discharge   

Max 

suction 

Volt 

Amps 

Weight 

MA0345X-6 

1/2 

12 gpm 

105 (ft) 

30 (ft) 

115/230 

5.2/2.6 

22 lbs 

MA0345X-8 

3/4 

14 gpm 

135 (ft) 

33 (ft) 

115/230 

6.5/3.3 

38 lbs 

MA0345X-9 

24 gpm 

151 (ft) 

33 (ft) 

115/230 

10.4/5.2 

40 lbs 

HALLMARK 

INDUSTRIES 

INC.

Summary of Contents for MA0345X-9

Page 1: ...uttered and properly lighted store properly all unused tools and equipment Keep visitors at a safe distance from the work areas result in death or serious injury indicates a hazard which if not avoide...

Page 2: ...the well as possible Use the fewest possible fittings especially elbows when connecting the pipe from the well point to the pump suction port The suction pipe should be at least as large as the suctio...

Page 3: ...cially elbows in the suction pipe The suction pipe should be at least as large as the suction port on the pump Assemble a foot valve and suction pipe see Figure 3 Make sure that the foot valve works f...

Page 4: ...2 Install one tee in the pump discharge port see Figure 5 Run a pipe from the pump discharge port to the inlet port of your tank The pipe size must be at least as large as the discharge port Install a...

Page 5: ...ly wires There must be a solid metal connection between the pressure switch and the motor for motor grounding protection If the pressure switch is not connected to the motor connect the green ground s...

Page 6: ...all the trapped air out of the piping A pump lifting water 25 may take as long as 15 minutes to prime After the pump has built up pressure in the system and shut off check the pressure switch operati...

Page 7: ...allow Well Jet Pumps 624 Estes Ave Schaumburg IL 60193 USA www hallmarkind com For reference only We do not stock spare parts Parts and repair Stainless steel jet pump Cast iron jet pump H A L L M A R...

Page 8: ...ck valve or foot valve is stuck shut Replace check valve or foot valve Pipes are frozen Thaw pipes Bury pipes below frost line Heat pit or pump house Foot valve and or strainer are buried in sand or m...

Page 9: ...t closer to the motor by hand Figure 1 STEP 2 Open the pressure switch cover flip the rubber grummets cone shape is now outside Figure 2 STEP 3 Connect the motor s cable wires to the pressure switch F...

Page 10: ...s exposed Figure 4 STEP 5 Adjust the pressure switch s in out psi to the desired setting according to the instruction on the back of pressure switch cover STEP 6 Put the pressure switch cover back on...