Troubleshooting

 

2. Lower suction line into  water and re-prime. If receding water level in well

 

causing  excess friction

 

Symptom

 

Possible Cause(s)

 

Corrective Action

 

Motor will not run

 

 

Disconnect switch  is off

 

Be sure switch  is on.

 

Fuse is blown  or circuit  breaker tripped

 

Replace fuse or reset circuit  breaker.

 

Starting switch  is defective

 

DISCONNECT  POWER; Replace starting switch.

 

Wires  at motor  are loose, disconnected,  or 

wired incorrectly

 

 

Refer to instructions on wiring   (Page 5). DISCONNECT POWER; check  and 
tighten all wiring.

 

Capacitor  voltage may  be hazardous. To discharge capacitor, 

hold  insulated  handle  screwdriver  BY THE HANDLE  and short capacitor 
terminals together. Do not touch metal screwdriver blade or capacitor terminals. 
If in doubt,  consult a qualified  electrician.

 

Pressure switch  contacts  are dirty

 

DISCONNECT  POWER and file contacts with emery board or nail file.

 

Motor  runs hot and overload 

kicks off

 

 

Motor  is wired  incorrectly

 

Refer to instructions on wiring.

 

Voltage is too  low

 

 

Check with power company. Install heavier wiring  if wire  size is too  small  (See

 

Electrical / Wiring Chart).

 

Pump cycles too frequently

 

See section  below  on too frequent cycling.

 

Motor  runs but no water  is 

delivered*

 

 
 

* Stop pump; then check 
prime before looking for 
other  causes. Unscrew 
priming  plug  and  see if 
water  is in priming hole.

 

 

Pump in new installation did not pick up 

prime through:

 

1. Improper priming

 

2. Air leaks

 

3. Leaking foot valve or check valve

 

In new installation:

 

1. Re-prime according to instructions.

 

2. Check all connections on suction line,  AVC, and ejector with soapy water  or 

shaving cream.

 

3. Replace foot valve or check valve.

 

Pump has lost prime  through:

 

1. Air leaks

 

2. Water level below suction pipe inlet

 

 

In installation  already in use:

 

1. Check all connections on suction line and  shaft seal.

 

 

exceeds 

25’ (7.6M),  a deep well pump  is needed.

 

Foot valve or strainer is plugged

 

Clean foot valve or strainer.

 

Ejector or impeller  is plugged

 

Clean ejector or impeller.

 

Check valve or foot  valve is stuck shut

 

Replace check  valve or foot valve.

 

Pipes are frozen

 

Thaw pipes. Bury pipes below  frost line.  Heat pit or pump house.

 

Foot valve and/or  strainer are buried  in 

sand or mud

 

Raise foot  valve  and/or  strainer above  bottom  of water source. Clean foot valve 

and strainer.

 

Water level  is too low for shallow well 

setup to deliver water

 

A deep well jet will be needed if your well is more  than 

25’ (7.6M) depth to 

water.

 

Pump does not deliver  water 

to full capacity  (Also check 
point 3 immediately  above)

 

 

Water level in well is lower  than estimated

 

A new nozzle and venturi combination  may be needed.

 

Steel piping  (if used) is corroded  or limed,

 

 

Replace with plastic pipe where possible, otherwise with new  steel pipe.

 

 

Piping is too small in size

 

Use larger piping.

 

Pump  delivers  water  but  does 

not shut off or pump cycles 
too frequently

 

 

Pressure switch  is out  of adjustment or 

contacts are welded  together

 

DISCONNECT  POWER; adjust or replace  pressure switch.

 

 

Faucets have been left  open

 

Close faucets.

 

Venturi, nozzle or impeller  is clogged

 

Clean venturi,  nozzle or impeller.

 

Standard pressure tank  is waterlogged  and 

has no air cushion

 

Drain  tank to air volume  control  port. Check AVC for defects. Check all 

connections for air leaks.

 

Pipes leak

 

Check connections.

 

Foot valve  leaks

 

Replace foot valve.

 

Pressure switch  is out  of adjustment

 

Adjust or replace  pressure switch.

 

Air charge too low in pre-charged tank

 

 

DISCONNECT  POWER and open faucets until  all pressure is relieved.  Using

 

tire  pressure gauge, check  air  pressure in tank at valve stem located on the tank. 
If less than  pressure  switch   cut-in   setting  (30-50  PSI), pump  air  into  tank  from 
outside  source until  air  pressure is 2 PSI less than  cut-in   setting  of switch. Check 
air  valve  for  leaks (use soapy solution)  and  replace  core  if necessary.

 

Air spurts from  faucets

 

 

Pump is picking  up prime

 

When  pump  has picked  up prime, it should pump solid water with no air.

 

Leak in suction  side of pump

 

Suction pipe is sucking air. Check joints  for leaks with soapy water.

 

Well is gaseous

 

Consult  factory  about  installing  a sleeve in the well.

 

Intermittent over-pumping of well. (Water 

drawn down below foot valve.)

 

Lower foot valve if possible, otherwise restrict pump  discharge.

 

 

 

 

 

 

 

HALLMARK 

INDUSTRIES 

INC.

Summary of Contents for MA0345X-9

Page 1: ...uttered and properly lighted store properly all unused tools and equipment Keep visitors at a safe distance from the work areas result in death or serious injury indicates a hazard which if not avoide...

Page 2: ...the well as possible Use the fewest possible fittings especially elbows when connecting the pipe from the well point to the pump suction port The suction pipe should be at least as large as the suctio...

Page 3: ...cially elbows in the suction pipe The suction pipe should be at least as large as the suction port on the pump Assemble a foot valve and suction pipe see Figure 3 Make sure that the foot valve works f...

Page 4: ...2 Install one tee in the pump discharge port see Figure 5 Run a pipe from the pump discharge port to the inlet port of your tank The pipe size must be at least as large as the discharge port Install a...

Page 5: ...ly wires There must be a solid metal connection between the pressure switch and the motor for motor grounding protection If the pressure switch is not connected to the motor connect the green ground s...

Page 6: ...all the trapped air out of the piping A pump lifting water 25 may take as long as 15 minutes to prime After the pump has built up pressure in the system and shut off check the pressure switch operati...

Page 7: ...allow Well Jet Pumps 624 Estes Ave Schaumburg IL 60193 USA www hallmarkind com For reference only We do not stock spare parts Parts and repair Stainless steel jet pump Cast iron jet pump H A L L M A R...

Page 8: ...ck valve or foot valve is stuck shut Replace check valve or foot valve Pipes are frozen Thaw pipes Bury pipes below frost line Heat pit or pump house Foot valve and or strainer are buried in sand or m...

Page 9: ...t closer to the motor by hand Figure 1 STEP 2 Open the pressure switch cover flip the rubber grummets cone shape is now outside Figure 2 STEP 3 Connect the motor s cable wires to the pressure switch F...

Page 10: ...s exposed Figure 4 STEP 5 Adjust the pressure switch s in out psi to the desired setting according to the instruction on the back of pressure switch cover STEP 6 Put the pressure switch cover back on...

Reviews: