![Hallde RG-200 Service Manual Download Page 7](http://html1.mh-extra.com/html/hallde-0/rg-200/rg-200_service-manual_3339594007.webp)
5
...
...
...
2. Disconnect lead wires from switch.
3. Remove 2 screws to remove switch and mounting platefrom machine.
4. Reassemble in reverse order. If switch adjustment is necessary, the hole tolerance for the
switch mounting bracket is the only available adjustment. The switch should open when
pin engages roller. Loosen the mounting bracket screws and re-position the switch
toward pusher plate shaft. Tighten screws and re-check operation. If activator pin does
not return smoothly when released, remove mounting bracket screws then remove pin
from bracket. Apply Omega 58 lubricant to the O-ring and re-install.
5. Perform ELECTRICAL CONTROLS TEST PROCEDURE as outlined in SERVICE PROCEDURES
AND ADJUSTMENTS.
RCNetwork
Note! Disconnect the electric power to the machine!
1. Remove right side machine housing panel as outlined under MACHINE HOUSING PANELS.
2. Remove wire tie at RC network.
2x screw