background image

 

 

SC-3H 

 

Command 

Response 

Function and Example 

FPx 

 

FPx<CR> 

 

Controls the Front Panel Lock Status 

FP?<CR> – Query current Front Panel Lock Setting 

FP1<CR> –  Turn on Front Panel Lock 

FP0<CR> –  Turn off Front Panel Lock  

(Factory Default)

 

ST 

System status 

Queries system status 

ST<CR> –  Query the current system status 

Current Status for the commands below: 

FW?, PW?,  MUT?, FP?, AU?, AT?, AP?,  ED?,  XB? 

and XP? 

XBx 

 

XBx<CR> 

 

Controls the RS-232 Out Baud Rate 

XB?<CR> – Query current Output Baud Rate Setting 

XB4<CR> –  Set Baud Rate to 9600  

(Factory Default)

 

 

The baud rate can be set to any of the following: 

XB1 = 1200, XB2 = 2400, XB3 = 4800 

XB4 = 9600, XB5 = 19200, XB6 = 38400 

XB7 = 57600, XB8 = 115200 

XPx 

 

XPx<CR> 

 

Controls the RS-232 Out Parity 

XP?<CR> – Query current Output Parity Setting 

XP0<CR> –  Set Parity to ‘NONE’  

(Factory Default)

 

XP1<CR> –  Set Parity to ‘EVEN’ 

XP2<CR> –  Set Parity to ‘ODD’ 

XT 

 

XT<CR> 

 

Transmit from RS-232 OUT with specific baud and parity 

Terminated with <0x17><0x0D> 

SPx 

 

SPx<CR> 

Controls the Serial Data Pass-Thru Status 

SP?<CR> – Query current Serial Pass-Thru Setting 

SP1<CR> –  Turn on Serial Pass-Thru 

SP0<CR> –  Turn off Serial Pass-Thru  

(Factory Default)

 

BPx or 

BPx,y 

BPx<CR> 

BPx,y<CR> 

Controls transmission of stored serial commands 

‘x’ is from 0 to 7, ‘y’ is either 1 (on) or 0 (off) 

BP?<CR> – Query current Button Press Status 

BP0<CR> –  Simulates pressing button #0 

BP1,0<CR> –  Simulates turning button #1 off 

AUx 

 

AUx<CR> 

Controls AUTO DETECT Mode 

AU?<CR> – Query current Auto Detect Mode Status 

AU1<CR> –  Auto Detect Mode Active 

AU0<CR> –  Auto Detect Mode In-Active 

(Factory 

Default)

 

ATx 

ATx<CR> 

Controls the Auto Detection Method Settings 

AT?<CR> – Query current Auto Detection setting 

AT0<CR> –  Auto Detection Disabled 

(Factory Default)

 

AT1<CR> –  +5VDC on HDMI INPUT 

AT2<CR> –  Video on HDMI INPUT 

Auto Detect must be active (

AU1

) for a Trigger to occur. 

Disabling Auto Detection will turn off Auto Detect (

AU0

). 

Summary of Contents for SC-3H

Page 1: ...User s Manual SC 3H MULTI FORMAT PRESENTATION SWITCHER RS 232 CONTROLLER UMA1256 Rev 2 Copyright 2017 Hall Research Inc All rights reserved 1163 Warner Ave Tustin CA 92780 Phone 1 714 641 6607...

Page 2: ...Any other trademarks mentioned in this manual are acknowledged as the property of the trademark owners FCC RADIO FREQUENCY INTERFERENCE STATEMENT This equipment can radiate radio frequency energy and...

Page 3: ...isplay and when the SC 3H is turned on it will send the on command to the display and upon turning the device off an off command will be issued The power commands can also function automatically In Au...

Page 4: ...l command EDID management Supports VGA HDMI MHL on HDMI 1 and DVI Locking power supply input connector Compact Rugged Reliable and Economical 2 1 Package Contents Qty 1 SC 3H Qty 1 5V DC Universal DC...

Page 5: ...OFF commands for external devices the unit will send those commands as it turns on or off To enter or exit Auto Power Command Mode press and hold the button for 7 seconds POWER AUTO LED This LED show...

Page 6: ...to a compatible video source VGA HD IN Connect the VGA connector to a compatible video source L R IN Connect the 3 5mm jack to compatible line level audio source This signal is only available when us...

Page 7: ...w level microphones the Hall Research Model HR 101 S may work for your needs In most classroom installations the wireless microphone present may have a line level output Use the following diagram for...

Page 8: ...hown as CR in table below Invalid input spaces and line feed characters 0x0A are ignored RS 232 communication at the rear connector is configurable factory default is 9600 bps 8 Bit No Parity 1 Stop b...

Page 9: ...Set Parity to ODD XT XT CR Transmit from RS 232 OUT with specific baud and parity Terminated with 0x17 0x0D SPx SPx CR Controls the Serial Data Pass Thru Status SP CR Query current Serial Pass Thru Se...

Page 10: ...ensing different parameters of the currently selected input source Source Video 5V 5V from source detected will cause the ON string to be sent out 5V from source lost for more than the programmed OFF...

Page 11: ...If you still are not able to get the system working properly contact Hall Research support preferably via email or via www hallresearch com with a detailed description of the issue and the troubleshoo...

Page 12: ...1200 2400 4800 9600 19200 38400 57600 or 115200 USB 1 Mini B General Power Supply 100 VAC to 240 VAC 47 63 Hz External 5 VDC Temp humidity Storage 40 to 158 F 40 to 70 C 10 to 90 non condensing Operat...

Page 13: ...SC 3H 13...

Page 14: ......

Page 15: ......

Page 16: ...ght 2017 Hall Research Inc All rights reserved Toll free in the U S 800 959 6439 Email support hallresearch com Hall Research 1163 Warner Ave Tustin CA 92780 www hallresearch com CUSTOMER SUPPORT INFO...

Reviews: