SC-3H
9
Command
Response
Function and Example
FPx
FPx<CR>
Controls the Front Panel Lock Status
FP?<CR> – Query current Front Panel Lock Setting
FP1<CR> – Turn on Front Panel Lock
FP0<CR> – Turn off Front Panel Lock
(Factory Default)
ST
System status
Queries system status
ST<CR> – Query the current system status
Current Status for the commands below:
FW?, PW?, MUT?, FP?, AU?, AT?, AP?, ED?, XB?
and XP?
XBx
XBx<CR>
Controls the RS-232 Out Baud Rate
XB?<CR> – Query current Output Baud Rate Setting
XB4<CR> – Set Baud Rate to 9600
(Factory Default)
•
The baud rate can be set to any of the following:
XB1 = 1200, XB2 = 2400, XB3 = 4800
XB4 = 9600, XB5 = 19200, XB6 = 38400
XB7 = 57600, XB8 = 115200
XPx
XPx<CR>
Controls the RS-232 Out Parity
XP?<CR> – Query current Output Parity Setting
XP0<CR> – Set Parity to ‘NONE’
(Factory Default)
XP1<CR> – Set Parity to ‘EVEN’
XP2<CR> – Set Parity to ‘ODD’
XT
XT<CR>
Transmit from RS-232 OUT with specific baud and parity
Terminated with <0x17><0x0D>
SPx
SPx<CR>
Controls the Serial Data Pass-Thru Status
SP?<CR> – Query current Serial Pass-Thru Setting
SP1<CR> – Turn on Serial Pass-Thru
SP0<CR> – Turn off Serial Pass-Thru
(Factory Default)
BPx or
BPx,y
BPx<CR>
BPx,y<CR>
Controls transmission of stored serial commands
‘x’ is from 0 to 7, ‘y’ is either 1 (on) or 0 (off)
BP?<CR> – Query current Button Press Status
BP0<CR> – Simulates pressing button #0
BP1,0<CR> – Simulates turning button #1 off
AUx
AUx<CR>
Controls AUTO DETECT Mode
AU?<CR> – Query current Auto Detect Mode Status
AU1<CR> – Auto Detect Mode Active
AU0<CR> – Auto Detect Mode In-Active
(Factory
Default)
ATx
ATx<CR>
Controls the Auto Detection Method Settings
AT?<CR> – Query current Auto Detection setting
AT0<CR> – Auto Detection Disabled
(Factory Default)
AT1<CR> – +5VDC on HDMI INPUT
AT2<CR> – Video on HDMI INPUT
Auto Detect must be active (
AU1
) for a Trigger to occur.
Disabling Auto Detection will turn off Auto Detect (
AU0
).