background image

 

 

MULT-FORMAT PRESENTATION SWITCHER & CONTROLLER 

 

10 

 

Command 

Response 

Function and Example 

ISx 

ISx<CR> 

Input Selection 

IS?<CR> –  Query current input selection 

IS0<CR> – 

IS1<CR> –  Select HDMI #1 Input 

(Factory Default)

 

IS2<CR> –  Select HDMI #2 Input 

IS3<CR> –  Select VGA Input 

UIx 

UIx<CR> 

SW3-UI  Installed Selection 

UI?<CR> –  Query current SW3-UI Installed selection 

UI1<CR> –  SW3-UI Installed 

(Factory Default)

 

UI0<CR> –  SW3-UI 

NOT

 Installed 

APx 

APx<CR> 

Auto Detection Input Priority Selection 

AP?<CR> –  Query current Auto Detection Input Priority 

selection 

AP0<CR> –  Manual Controlled 

(Factory Default)

 

AP1<CR> –  Priority Controlled 

AP2<CR> –  Last Plugged 

 

5.2 Auto Power Video Detection Methods 

As mentioned earlier, when the power mode is in Auto Command, the SC-3H can send 

the user programmed ON/OFF RS-232 strings based on sensing different parameters of 

the currently selected input source. 

Source Video +5V

 –  

 

+5V from source detected will cause the ON string to be sent out. 

 

+5V from source lost for more than the programmed OFF Delay will cause the ON 

string to be sent out. 

 

The OFF Delay is programmable from 0 to 240 minutes. 

Factory default - 3 minutes

 

 

Source Video

 –  

 

TMDS Video Clock detected will cause the ON string to be sent out. 

 

TMDS Video Clock detected will cause the will cause the OFF string to be sent out 

after the OFF Delay mentioned above. 

 

5.3 Auto Input Selection and Input Priority 

This model can switch automatically to another input based on the following events. 

Manually Controlled

 – 

(Factory Default)

 

The user must select the desired input. 

 

Priority Controlled

 

The appropriate input is selected based on the priorities configured and whether video 

is being received. 

 

Last Plugged

 

The appropriate input is selected based on which input was last plugged in and 

whether video is being received. 

Summary of Contents for SC-3H

Page 1: ...User s Manual SC 3H MULTI FORMAT PRESENTATION SWITCHER RS 232 CONTROLLER UMA1256 Rev 2 Copyright 2017 Hall Research Inc All rights reserved 1163 Warner Ave Tustin CA 92780 Phone 1 714 641 6607...

Page 2: ...Any other trademarks mentioned in this manual are acknowledged as the property of the trademark owners FCC RADIO FREQUENCY INTERFERENCE STATEMENT This equipment can radiate radio frequency energy and...

Page 3: ...isplay and when the SC 3H is turned on it will send the on command to the display and upon turning the device off an off command will be issued The power commands can also function automatically In Au...

Page 4: ...l command EDID management Supports VGA HDMI MHL on HDMI 1 and DVI Locking power supply input connector Compact Rugged Reliable and Economical 2 1 Package Contents Qty 1 SC 3H Qty 1 5V DC Universal DC...

Page 5: ...OFF commands for external devices the unit will send those commands as it turns on or off To enter or exit Auto Power Command Mode press and hold the button for 7 seconds POWER AUTO LED This LED show...

Page 6: ...to a compatible video source VGA HD IN Connect the VGA connector to a compatible video source L R IN Connect the 3 5mm jack to compatible line level audio source This signal is only available when us...

Page 7: ...w level microphones the Hall Research Model HR 101 S may work for your needs In most classroom installations the wireless microphone present may have a line level output Use the following diagram for...

Page 8: ...hown as CR in table below Invalid input spaces and line feed characters 0x0A are ignored RS 232 communication at the rear connector is configurable factory default is 9600 bps 8 Bit No Parity 1 Stop b...

Page 9: ...Set Parity to ODD XT XT CR Transmit from RS 232 OUT with specific baud and parity Terminated with 0x17 0x0D SPx SPx CR Controls the Serial Data Pass Thru Status SP CR Query current Serial Pass Thru Se...

Page 10: ...ensing different parameters of the currently selected input source Source Video 5V 5V from source detected will cause the ON string to be sent out 5V from source lost for more than the programmed OFF...

Page 11: ...If you still are not able to get the system working properly contact Hall Research support preferably via email or via www hallresearch com with a detailed description of the issue and the troubleshoo...

Page 12: ...1200 2400 4800 9600 19200 38400 57600 or 115200 USB 1 Mini B General Power Supply 100 VAC to 240 VAC 47 63 Hz External 5 VDC Temp humidity Storage 40 to 158 F 40 to 70 C 10 to 90 non condensing Operat...

Page 13: ...SC 3H 13...

Page 14: ......

Page 15: ......

Page 16: ...ght 2017 Hall Research Inc All rights reserved Toll free in the U S 800 959 6439 Email support hallresearch com Hall Research 1163 Warner Ave Tustin CA 92780 www hallresearch com CUSTOMER SUPPORT INFO...

Reviews: