background image

 

 

MULT-FORMAT PRESENTATION SWITCHER & CONTROLLER 

 

12 

 

7.0 Specifications 

  Video  

Connectors  (2) Locking HDMI INPUT 

(1) VGA INPUT 

(1) Locking HDMI OUTPUT 

Standards 

DVI (single link) 

HDMI up to 12 bit color depth, 3D video HDCP 1.2 

Signal type  TMDS 

Resolutions  DVI or VGA signal   VGA (640x480) thru WUXGA (1920x1200) 

HDMI signal 

480i through 4K@30 Hz 4:4:4 or 4K@60 4:2:0 

  Audio 

Formats 

All HDMI Embedded Audio including: LPCM 7.1CH, Dolby TrueHD and DTS-HD Master 

Audio (32-192kHz sample rate). Analog audio output only supports two channel format. 

 

  Other Signals 

RS-232 

(1) DB9M 

RS-232 Baud Rate: 9600, N, 8, 1 

(factory default)

 

Configurable at 1200, 2400, 4800, 9600, 19200, 38400, 57600, or 115200 

USB 

(1) Mini-B 

  General 

Power Supply  100 VAC to 240 VAC, 47-63 Hz, External; 5 VDC 

Temp/humidity  Storage: -40 to +158 °F (-40 to +70 °C) / 10% to 90%, non-condensing 

Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%, non-condensing 

Typical DC 

Current Draw 

5 VDC, 2.0 A Power Supply 

ON:  650-750 mADC 

OFF: ~400 mADC 

Cooling 

Convection 

Enclosure type  Metal (Steel) 

Dimensions  1.25" H x 9.00" W x 4.3" D 

(32mm H x 229mm W x 109mm D) 

Depth excludes connectors 

Product weight  Model Only  

1.3 lb 

Kit (shipping)  

3.0 lb includes: SC-3H, power supply, power cord, USB cable, manual, 

and packaging 

Vibration 

ISTA 1A in carton (International Safe Transit Association) 

Safety 

CE 

EMI/EMC 

CE, FCC Class A 

MTBF 

90,000 hours (Calculated Estimate) 

Warranty 

3 years parts and labor 

Specifications are subject to change without notice

 

 

Summary of Contents for SC-3H

Page 1: ...User s Manual SC 3H MULTI FORMAT PRESENTATION SWITCHER RS 232 CONTROLLER UMA1256 Rev 2 Copyright 2017 Hall Research Inc All rights reserved 1163 Warner Ave Tustin CA 92780 Phone 1 714 641 6607...

Page 2: ...Any other trademarks mentioned in this manual are acknowledged as the property of the trademark owners FCC RADIO FREQUENCY INTERFERENCE STATEMENT This equipment can radiate radio frequency energy and...

Page 3: ...isplay and when the SC 3H is turned on it will send the on command to the display and upon turning the device off an off command will be issued The power commands can also function automatically In Au...

Page 4: ...l command EDID management Supports VGA HDMI MHL on HDMI 1 and DVI Locking power supply input connector Compact Rugged Reliable and Economical 2 1 Package Contents Qty 1 SC 3H Qty 1 5V DC Universal DC...

Page 5: ...OFF commands for external devices the unit will send those commands as it turns on or off To enter or exit Auto Power Command Mode press and hold the button for 7 seconds POWER AUTO LED This LED show...

Page 6: ...to a compatible video source VGA HD IN Connect the VGA connector to a compatible video source L R IN Connect the 3 5mm jack to compatible line level audio source This signal is only available when us...

Page 7: ...w level microphones the Hall Research Model HR 101 S may work for your needs In most classroom installations the wireless microphone present may have a line level output Use the following diagram for...

Page 8: ...hown as CR in table below Invalid input spaces and line feed characters 0x0A are ignored RS 232 communication at the rear connector is configurable factory default is 9600 bps 8 Bit No Parity 1 Stop b...

Page 9: ...Set Parity to ODD XT XT CR Transmit from RS 232 OUT with specific baud and parity Terminated with 0x17 0x0D SPx SPx CR Controls the Serial Data Pass Thru Status SP CR Query current Serial Pass Thru Se...

Page 10: ...ensing different parameters of the currently selected input source Source Video 5V 5V from source detected will cause the ON string to be sent out 5V from source lost for more than the programmed OFF...

Page 11: ...If you still are not able to get the system working properly contact Hall Research support preferably via email or via www hallresearch com with a detailed description of the issue and the troubleshoo...

Page 12: ...1200 2400 4800 9600 19200 38400 57600 or 115200 USB 1 Mini B General Power Supply 100 VAC to 240 VAC 47 63 Hz External 5 VDC Temp humidity Storage 40 to 158 F 40 to 70 C 10 to 90 non condensing Operat...

Page 13: ...SC 3H 13...

Page 14: ......

Page 15: ......

Page 16: ...ght 2017 Hall Research Inc All rights reserved Toll free in the U S 800 959 6439 Email support hallresearch com Hall Research 1163 Warner Ave Tustin CA 92780 www hallresearch com CUSTOMER SUPPORT INFO...