Page
52
SmartFOAM
Figure 34
: SmartFOAM Controller Unit Mounting Dimensions
CONTROLLER UNIT
The controller unit mounts in the operator panel of the
apparatus. The display is secured with four #6 pan head
screws and nuts (see Figure 34
Controller Unit Mounting Dimensions
The controller requires a 2.0
” (52mm) minimum
clearance from the back of the operator panel to allow
proper connection of cables.
Single tank models refer to Figure 35
❑
Connect C1 of the controller harness to the “B”
connector on the rear of the controller unit.
❑
C
onnect C6 of the controller harness to the “C”
connector on the rear of the controller unit.
❑
Connect C13 on the controller harness to C14 of
the pump harness.
❑
Connect C7 of the controller harness to the water
flow sensor input module.
❑
Connect C3 of the controller harness to the water
flow sensor (paddlewheel).
❑
Connect C10 of the pump harness to the low
foam sensor.
❑
C2 and C4 of the controller harness are used for
options (remote start stop and CAN
communication respectively).
❑
C6, C7, C8, C15, and C16 of the pump harness
are pre-connected by Hale Products at the
factory.
Dual tank models refer to Figure 36
❑
Connect C1 of
the controller harness to the “B”
connector on the rear of the controller unit.
❑
C
onnect C6 of the controller harness to the “C”
connector on the rear of the controller unit.
❑
Connect C13 on the controller harness to C14 of
the pump harness.
❑
Connect C7 of the controller harness to the water
flow sensor input module.
❑
Connect C3 of the controller harness to the water
flow sensor (paddlewheel).
❑
Connect C8 of the pump harness to the tank A
selector.
❑
Connect C9 of the pump harness to the tank B
selector.
❑
Connect C10 of the pump harness to the tank A
low foam sensor.
❑
Connect C11 of the pump harness to the tank B
low foam sensor.
❑
C2 and C4 of the controller harness are used for
options (remote start stop and CAN
communication respectively).
❑
C6, C7, C15, and C16 of the pump harness are
pre-connected by Hale Products at the factory.
Notes:
Allow a service loop on the controller
unit’s harness
connections to prevent
“pulling” of the wires or
connectors during body and frame flex.
Summary of Contents for SmartFOAM 1.7AHP
Page 3: ...Page 2 SmartFOAM NOTES...
Page 14: ...Page 13 SmartFOAM Figure 2 3 3 and 5 0 Foam Pump Installation Envelope Dimensions...
Page 15: ...Page 14 SmartFOAM SYSTEM DIAGRAM Figure 3 Typical Hale SmartFOAM 2 1A and 1 7AHP System...
Page 16: ...Page 15 SmartFOAM Figure 4 SmartFOAM 3 3 5 0 6 5 Single Tank System with In line Strainer...
Page 17: ...Page 16 SmartFOAM Figure 5 SmartFOAM 3 3 5 0 6 5 Single Tank withMSTandIn lineStrainer...
Page 18: ...Page 17 SmartFOAM Figure 6 SmartFOAM 3 3 5 0 6 5 Single Tank withMSTandFSSeriesStrainer...
Page 19: ...Page 18 SmartFOAM Figure 7 SmartFOAM 3 3 5 0 6 5 Dual Tank withMDTIIandIn lineStrainer...
Page 20: ...Page 19 SmartFOAM Figure 8 SmartFOAM 3 3 5 0 6 5 Dual Tank withMDTIIandFSSeriesStrainer...
Page 21: ...Page 20 SmartFOAM Figure 9 SmartFOAM 3 3 5 0 6 5 Dual Tank with ADTandIn lineStrainer...
Page 22: ...Page 21 SmartFOAM Figure 10 SmartFOAM 3 3 5 0 6 5 Dual Tank with ADTandFSSeriesStrainer...
Page 40: ...Page 39 SmartFOAM Figure 18 Typical 4 Inch Check Valve Installation Midship Pump...
Page 51: ...Page 50 SmartFOAM Figure 33 ADT Option Air Hose Connections Part 2...
Page 68: ...Page 67 SmartFOAM NOTES...
Page 80: ...79 Page 79 SmartFOAM NOTES...