PLUMBING INSTALLATION
Hale SmartFOAM System plumbing diagram is located below. The diagram provides recommended guidelines for the
installation of system components that handle water, foam concentrate and foam solution. The sequence in which the
plumbing installation is completed depends on your individual installation requirements.
IMPORTANT!
AFTER INSTALLATION, MAKE SURE ALL PIPES, HOSES AND TUBES ARE PROPERLY SUPPORTED USING THE
BEST INDUSTRY PRACTICES. USE A SUITABLE PIPE SEALING COMPOUND AT ALL JOINTS.
WATER AND FOAM SOLUTION PLUMBING
Use best industry practices when installing the water and foam solution piping runs. Use a suitable pipe sealing compound
at all joints.
CHECK VALVE MANIFOLD
Hale pre-made stainless steel foam manifolds are recommended. The manifolds are available in kits and eliminate the extra
labor and leaks from large pipe thread connections.
The manifolds use 3” (76mm) Victaulic connections and are available in
single or dual check valve configurations. Figure 16
: Check Valve Manifold Installation
manifold installation.
Figure 16
: Check Valve Manifold Installation
Note:
When the manifold is installed the drain tap that must be placed in the
“down” position and plumbed to an individual
drain.
Summary of Contents for SmartFOAM 1.7AHP
Page 3: ...Page 2 SmartFOAM NOTES...
Page 14: ...Page 13 SmartFOAM Figure 2 3 3 and 5 0 Foam Pump Installation Envelope Dimensions...
Page 15: ...Page 14 SmartFOAM SYSTEM DIAGRAM Figure 3 Typical Hale SmartFOAM 2 1A and 1 7AHP System...
Page 16: ...Page 15 SmartFOAM Figure 4 SmartFOAM 3 3 5 0 6 5 Single Tank System with In line Strainer...
Page 17: ...Page 16 SmartFOAM Figure 5 SmartFOAM 3 3 5 0 6 5 Single Tank withMSTandIn lineStrainer...
Page 18: ...Page 17 SmartFOAM Figure 6 SmartFOAM 3 3 5 0 6 5 Single Tank withMSTandFSSeriesStrainer...
Page 19: ...Page 18 SmartFOAM Figure 7 SmartFOAM 3 3 5 0 6 5 Dual Tank withMDTIIandIn lineStrainer...
Page 20: ...Page 19 SmartFOAM Figure 8 SmartFOAM 3 3 5 0 6 5 Dual Tank withMDTIIandFSSeriesStrainer...
Page 21: ...Page 20 SmartFOAM Figure 9 SmartFOAM 3 3 5 0 6 5 Dual Tank with ADTandIn lineStrainer...
Page 22: ...Page 21 SmartFOAM Figure 10 SmartFOAM 3 3 5 0 6 5 Dual Tank with ADTandFSSeriesStrainer...
Page 40: ...Page 39 SmartFOAM Figure 18 Typical 4 Inch Check Valve Installation Midship Pump...
Page 51: ...Page 50 SmartFOAM Figure 33 ADT Option Air Hose Connections Part 2...
Page 68: ...Page 67 SmartFOAM NOTES...
Page 80: ...79 Page 79 SmartFOAM NOTES...