FAULT FINDING
EFFECT CAUSE
ACTION
Compressor overheats
No water supply or restricted flow
Turn on water supply.
Check oil cooler pipe work
for obstructions
Unable to produce foam
solution
FoamLogix not operating
Switch on engine ignition
Switch on FoamLogix
No Foam in tank
Refill with foam agent
No air injection
CAFS switch not on
Turn CAFS switch on
Low foam switch activated
(If fitted)
Refill foam Tank
Air and liquid not mixing
(Slugflow)
Depleted foam supply (Low level
switch not fitted)
Foam % set too low
Refill foam tank
Increase foam % setting
Surging of hose and
pressure gauge.
Insufficient air pressure in hose
Increase compressor speed
if not at maximum.
Reduce nozzle diameter.