Handling Excess
Cable
Excess cable must not be allowed to hang free,
but must be attached to the chassis to prevent
damage due to vibration and abrasion.
Cable lengths less than 40” (1 m) should be
coiled into loops of 4”- 6” (100-150 mm)
diameter.
Excess length which will not form a complete
loop may be left to hang in partial loops having
a cable bend radius of 2” (50 mm) minimum.
Cable lengths greater than 40” (1 m) should be
coiled and then flattened in the center ‘B’ to
produce a ‘dog bone’ shape.
The resulting loops at the end must have a
minimum bend radius of 2” (50 mm). Use
cable ties to fix the cable in the flattened loop
shape.
Looped cables must be staggered, do not loop
cables in the same place.