27
Operation
Error code
Cause
Solution
2.6.6.1.
Turn hydraulic valve for sweepings container
(overloaded, defective or not connected)
Check hydraulic valve Y7/Y6, ignition key OFF/ON and
restart engine
2.6.6.2.
Hydraulic valve for sweepings container "Raise/
Lower" (overloaded, defective or not connected)
Check hydraulic valve Y9/Y8, ignition key OFF/ON and
restart engine
3.4.5.6.
If the vehicle is overloaded, the engine speed drops
and the engine is switched off.
Ignition key OFF/ON and restart engine
3.6.6.1.
Fuel valve (with gasoline/LPG)
(overloaded, defective or not connected)
Stop engine signal (with diesel)
(overloaded, defective or not connected)
With gasoline/LPG: Check fuel valve, ignition key OFF/
ON and restart engine
With diesel: Check control relay K10, check actuator
Y1 (engine stop), ignition key OFF/ON and restart
engine
3.6.6.2.
Starter release is overloaded, defective or not con-
nected
Ignition key OFF/ON and restart engine
3.6.6.3.
Accelerator position detector is defective or has
been manipulated
Move the accelerator and set to the neutral position,
ignition key OFF/ON and restart the engine
3.6.6.4.
Timeout seat contact, i.e. no driver has been
detected on the seat for a longer period. Seat con-
tact has been manipulated of defective
Actuate the seat contact, ignition key OFF/ON and
restart the engine