26
Maintenance/Service
Machine switches off
- Excessive pad ground pressure
- Pad has contact with cover
- Reduce pad ground pressure. Oper-
ate machine in green LED range
- Centre or replace pad
- Check pad size
Short operation time with one battery
charge cycle
- One of the batteries is damaged
- Battery is used out
- Excessive pad ground pressure
- Wrong pad type
- Replace battery (After Sales Service)
- Replace battery (After Sales Service)
- Reduce pad ground pressure
- Use prescribed pad type
Battery charger does not switch on
- Missing connection cable
- Incorrect charging order
- Low discharge of battery
- Check connection cable
- Read operating instructions of the
charger unit
- Replace battery
Malfunction
Possible cause
Remedy