57
Operation
Table 1
Error code
Fault
Cause
Solution
2.3.5.1
Side brush remains stopped
because the thermostatic
switch has been tripped.
The motor has overheated.
Foreign bodies have possibly
jammed between the side brush
and shaft (e.g. tape and such).
• Check the side scrubbing brush for
foreign bodies and remove them, as
necessary.
• Allow the motor to cool down.
• If the problem reoccurs, determine the
cause of overheating; contact an
authorized Hako service center, if
necessary.
2.3.6.1.
Side scrubbing brush
remains stopped because
the anti-blocking system
has been tripped.
Foreign bodies (e.g. tape or
such)are blocking the side
scrubbing brush.
• Check the side scrubbing brush for
foreign bodies and remove them, as
necessary.
2.3.6.4.
Side brush holding
attachment has been
switched off because the
anti-blocking system has
been tripped.
Foreign bodies between the side
scrubbing unit and vehicle.
• Check the side scrubbing unit for foreign
bodies and remove them, as necessary.
1.4.6.1.
Squeegee holding
attachment has been
switched off because the
anti-blocking system has
been tripped.
• Foreign bodies between the
squeegee and vehicle.
• Squeegee is jammed.
• Check the squeegee attachment for
foreign bodies and remove them, as
necessary.
• Free the squeegee.