7
4. Place the HAKKO FU-6001 on the iron unit fixing assembly and tighten the two screws.
●
How to position the tip after replacement
After replacement, you need to position the tip.
Loosen the positioning screw and align the tip with the reference point set in the previous page.
To prevent the upward movement and misalignment of the tip, tighten the screws while pressing
the tip from the top.
Tighten
16
●
Installing the iron to the feeder unit
Tighten the feeder unit set screws as shown in the figure below.
Now you can install the HAKKO FU-6001 to the feeder unit.
●
The HAKKO FU-6001 maintenance
After the HAKKO FU-6001 is used for soldering, the unit (particularly the flux protector) is heavily
deposited with flux.
If you insert a tip into the unit with flux deposit in or around the hole of the flux protector,
the flux may be entrained into the hole and deposit on the terminal of the HAKKO FU-6001,
causing poor contact (sensor error).
Regulary wipe off the flux using alcohol.
If wiping the flux protector did not remove the flux or dirt or the flux protector was deformed,
replace it.
Flux protector
Part No.
:
BX1027
size
:
M3×30
CAUTION
NEVER use thinner or other solvent to wipe the unit and the flux protector.
Doing so may melt the resin part.
Positioning screw
①
Positioning screw
②