8. PARTS LIST

NOTE:

Spare or repair parts do not include 

mounting screws, if they are not listed 

on the specifications. Screw must be 

ordered separately.

l

 

Set

l

 

Parts

Item 

No.







Part No.

B3078
B3079
B3080
B3081
B1319

B2004
B2005
B2015

Part Name

Panel
Upper case
P.W.B.
Handpiece holder
Power cord

Knob
Knob mount
Cord stopper

Specifications

For control
with screw, spring
3-wired cord & 
American plug

Item 

No.








Part No.

B2016
B2017
B2103
B2224
B2836
B2300
B2838
B2852

Part Name

Rubber stopper
Hex. wrench
Wiring board for switch
Fuse / 2A
Transformer
Heat resistant pad
Lower case
Power switch

Specifications

Set of 2
1.5 mm

UL
120V

6. MAINTENANCE

Performing proper and periodic maintenance ensures proper operation of the tool and extends the product 

life. Apply the following service procedure as dictated by the conditions of the usage.

l

Blade

1. Maintenance

2. Interruption

If the blades become oxidized, it will be difficult to melt the 

insulation. Remove oxide and stripped insulation waste from the 

blades with a wire brush. Use light pressure when cleaning the 

blades. Excessive pressure can damage the blades and shorten 

blade life. 
Do not clean the blades when they are hot.

When  not  using  the  unit,  be  sure  to  place  it  in  the  handpiece 

holder.  Operating  the  blades  at  high  temperature  without 

stripping  insulation  for  extended  time  may  shorten  the  heating 

element life. If you will not use the unit for a long time, turn off the 

power switch.

Model No.

FT800-01

Plug

3-wired cord & American plug

Country

U. S. A.

Voltage

120V

Cord

SVT

Instruction Manual

JEC

Standard

MET

n

Disconnection of heating 

element

n

Continuity check

l

How to replace the fuse

Check the heating element for electric error.

Measure the heater element at room temperature (15 to 25

°

C; 59 

to 77

°

F).

Normal detection is 9

 

±

10%. If resistance value is abnormal, 

replace the blade with a new one.

1. Attach normal blades (with normal heater resistance) to both 

handles.

2. Measure the resistance between the connector pins.

Between pin 1 and pin 5: 8.1 to 9.9

.

If the resistance value is different from the above figures, 

replace the FT-8001.

Desolder the fuse and replace it with a new fuse. (Refer to the 

figure in “Parts list”.

l

Check

WARNING

Unless otherwise specified, turn off 

the power switch and pull the power 

plug out before performing the 

following procedures.

1

5

l

Removing wire insulation

1. Align the wire end to the lead adjuster.

2. Pinch the wire in the proper hole between the 

blades in accordance with the wire diameter. The 

pinched section will be melted by the heated 

blades. (Refer to the drawing of the blade in the 

parts list.)

3. Turn the wire and blade to spread the heat 

uniformly over the insulation. 

4. Slide the blade toward the end of the insulation.

l

Use of reverse action switch 

By operating the reverse action switch, the blade 

opening or closing conditions can be selected 

according to your work details.

l

When the indication mark “R” is displayed: The 

blades are closed and can be opened by 

pressing the back of the button.

l

When the indication mark “N” is displayed: The 

blades are in normal position and can be closed 

by pressing the front side of the button.

l

 

Handpiece

Item No.


Part No.

G1-1601
G1-1602

Part Name

Blade / 18-28AWG
Straight blade

Specifications

Standard

Item No.



Part No.

FT8001-01

B3077
B3089

Part Name

FT8001/24V-64W
Lead adjuster A
Lead adjuster B

Specifications

l

 

Wire stripper blade

7. TROUBLE SHOOTING GUIDE

WARNING

• Before repairing the unit, be sure to disconnect the power plug. Failure to do so may cause 

electric shock. 

l

The unit does not operate even 

when the power switch is turned 

on.

l

The power save lamp flashes.

l

The power save lamp flashes 2 

times consecutively.

CHECK

: Is the power cord or the connection plug disconnected?

ACTION

: Connect the power cord and the connection plug.

CHECK

: Is the fuse blown?

ACTION

: Investigate why the fuse blew and then replace the fuse. 

Even if the cause can not be determined, replace the fuse. 

If the fuse blows again, send the entire unit for repair.

CHECK

: Are the blades inserted firmly?

ACTION

: Insert the blades fully.

CHECK

: Is the connection cord disconnected? Is the heating 

element broken?

ACTION

: Refer to how to check the disconnection of connection cord 

and breakage of the heating element.

ACTION

: Turn on the power switch again.

CHECK

: If the same phenomenon occurs again, it is assumed that 

the unit has undergone a system error. Return the unit for 

repair.