1
1. PACKING LIST
HAKKO FR-803B station ......................................... 1
Power cord .............................................................. 1
Handpiece holder .................................................... 1
Pads (ø3 mm (0.12 in.), ø5 mm (0.20 in.), ø7.6 mm (0.3 in.)) .....2 each
Vacuum pipe control knob (L) .................................. 1
Control card ............................................................. 1
Connecting cord ...................................................... 1
Instruction manual ................................................... 1
* This product does not include a nozzle. A large
selection of nozzles are available for the HAKKO
FR-803B. Select the nozzle or nozzles suitable
for the work to be performed.
Check the contents of the HAKKO FR-803B package
and confirm that all the items listed below are included.
Control card
HAKKO FR-803B station
Handpiece holder
2. SPECIFICATIONS
Name
HAKKO FR-803B
Power consumption 100V-310W 110V-370W 120V-440W
220V-590W 230V-650W 240V-700W
●
Station
Power consumption 100V 30 W
110-120V 40W
220-240V 50W
(Standby, 100-120V 4W, 220-240V 4W)
Capacity
5
l
/min to more than 20
l
/min
Control temperature 100 ~ 500°C/200 ~ 930°F (sensor)
Modes
Manual/Auto
Timer
50 file/step
External dimensions 160 (W)
×
145 (H)
×
230 (D) mm/
6.3
×
5.7
×
9.1 in.
Weight
5 kg (11.02 lb.)
●
Handpiece
Power
consumption
100V-280W 110V-330W 120V-400W
220V-540W 230V-600W 240V-650W
Total length
(w/o cord)
200mm/7.9 in.
Weight (w/o
cord)
200 g/0.44 lb.
2 for each pad
Power cord
Vacuum pipe control
knob (L)
NOTE:
* This product is protected against electrostatic discharge.
* Specifications and design are subject to change without
notice.
Electrostatic Protection
This product includes such features as electrically
conductive plastic parts and grounding of the handpiece
and station as measures to protect the device to be
soldered from the effects of static electricity. Be sure to
observe the following instructions:
1. The handle and other plastic parts are not insula-
tors, they are conductors. When replacing parts
or repairing, take sufficient care not to expose live
electrical parts or damage insulation materials.
2. Be sure to ground the unit during use.
Connecting cord