7. PARAMETERS
●
Parameter change method
To enter in Parameter Change mode, turn on
the power switch while pressing the
and
buttons simultaneously.
1. °C/°F change
Press the
or
button, select "C"
(Celsius) or "F" (Fahrenheit) and press the
button to enter.
2. Change of power save time
Press the
or
select 30 min, 60 min or
∞ and press the
button to enter.
3. Change of timer display unit
Press the
or
button, select “n” (min)
or “S” (sec) and press the
button to enter.
4. Change of countdown method
Press the
or
select “o” (Opened
timer) or “c” (Closed timer) and press the
button to enter. (See the table on page 7.)
5. Change of card-lock function
Press the
or
button, select 1 or 2 and
press the
button to enter.
The parameter input mode is completed,
is displayed and then returned to the
normal mode.
Parameter
Parameter display
Initial setting
°C/°F change
°C or °F
C (°C)
Power saving time (30 min/60 min/∞)
30, 60 or ∞
30 (30 min)
Timer display unit (min/sec)
n or S
n (min)
Change of count-down method (Opened timer/closed timer)
o or c
o
(opened timer)
Change of control card lock function (Normal/single lock)
1 or 2
1 (normal)
Change of forced air shutoff function (ON (Enable)/OFF (Disable))
0 or 1
0 (OFF)
* In case of simple lock, the change of file number in AUTO mode can be changed without inserting the control card.
* The forced air shutoff function is inoperative when the temperature readout is 380°C or higher, even if the function is set to be enabled.
CAUTION
Be sure to insert the control card into the card slot
before changing.
Press the
button.
Press the
or
button.
Press the
or
button.
Press the
button.
Press the
button.
Press the
button.
Press the
button.
●
Initial resetting method
CAUTION
Be sure to insert the control card into the card slot
before initial resetting.
Turn the power switch ON while simultaneously
pressing the
,
and
buttons to reset
to the initial set values upon shipment from the
factory. The mode is displayed in MANUAL.
CAUTION
If the power is turned OFF
before the parameter setting
procedure is completed (
is not displayed), the new
setting value will not be stored
in memory
.