1
Cleaning Pin (for ø1.0 mm
[0.04 in] nozzle)
Nozzle wrench
Ceramic paper Filter
(for handpiece)
Filter
(for station)
Cleaning Pin
(for heating element)
Cleaning Drill (for ø1.0 mm
[0.04 in] nozzle)
HAKKO FH-410
Power cord
Tool box
HAKKO
FR-410
×1
×1
×1
×1
×2
×4
HAKKO FR-410 station
HAKKO FR-4103 handpiece
(with N61-05 (ø1.0 mm [0.04 in] type S) nozzle)
Power cord
1
1
1
HAKKO FH-410 iron holder
(with cleaning sponge)
Tool box
Instruction Manual
1
1
1
2. SPECIFICATIONS
●
HAKKO FR-410
Power consumption
Temperature range
Temperature stability
190 W
330 - 450
℃
(620 - 850
℉
)
±5
℃
(±9
℉
) at idle temperature
●
Station
Output
Vacuum generator
Vacuum pressure (max.)
Suction flow
Dimensions
Weight
AC 24 V
Vacuum pump, double cylinder type
80 kPa (600 mmHg)
15 L/min.
165 (W) × 137 (H) × 244 (D) mm
(6.5 × 5.4 × 9.6 in.)
4.8 kg (10.6 lb.)
●
Handpiece (HAKKO FR-4103)
Part name
Power consumption
Nozzle to ground resistance
Nozzle to ground potential
Cord
Length (w/o cord)
Weight (w/o cord)
HAKKO FR-4103
140 W (24 V)
<2
Ω
<2 mV
1.2 m (4 ft.)
168 mm (6.6 in.) with N61-05 nozzle
190 g (0.42 lb.) with N61-05 nozzle
* The temperature was measured using the HAKKO FG-101
Soldering Tester.
* This product is protected against electrostatic discharge.
* Specifications and design are subject to change without notice.
1. PACKING LIST AND PART NAMES
Please check to make sure that all items
listed below are included in the package.
Nozzle (N61 series)
Filter pipe
Trigger
HAKKO FR-4103
CAUTION
■
Electrostatic Protection
2
3. WARNINGS, CAUTIONS AND NOTES
WARNING
CAUTION
To prevent accidents or damage to the HAKKO FR-410, be sure to observe the following:
●
Do not use the unit for applications other than desoldering.
●
Do not strike the handpiece against hard objects to remove excess solder. This will
damage the handpiece.
●
Do not modify the HAKKO FR-410.
●
Use only genuine HAKKO replacement parts.
●
Do not allow the HAKKO FR-410 to become wet, or use it when hands are wet.
●
Be sure to hold the plug when inserting or removing the handpiece and power cords.
●
Be sure the work area is well ventilated. Desoldering produces smoke.
●
While using the HAKKO FR-410, don't do anything which may cause bodily harm
or physical damage.
When power is ON, the nozzle will be hot. To avoid injury or damage to
personnel and items in the work area, observe the following:
●
Do not touch the nozzle or the metal parts near the nozzle.
●
Do not allow the nozzle to come close to, or touch, flammable materials.
●
Inform others in the area that the unit is hot and should not be touched.
●
Turn the power off when not in use, or left unattended.
●
Turn the power off when changing parts or storing the HAKKO
FR-410.
●
This unit is for counter or workbench use only.
●
This appliance can be used by children aged from 8 years and above
and persons with reduced physical, sensory or mental capabilities or
lack of experience and knowledge if they have been given supervision
or instruction concerning use of the appliance in safe way and
understand the hazards involved.
●
Children shall not play with the appliance.
●
Cleaning and user maintenance shall not be made by children
without supervision.
Warnings, cautions and notes are placed at critical points in this manual to direct the
operator’s attention to significant items. They are defined as follows:
WARNING:
Failure to comply with a WARNING may result in serious injury or death.
CAUTION:
Failure to comply with a CAUTION may result in injury to the operator,
or damage to the items involved.
NOTE:
A NOTE indicates a procedure or point that is important to the process
being described.