13
Parameter name
Temp Mode
ShutOff Set
Timer**
Vacuum Mode
Vacuum Time***
Auto Sleep
Timer**
Sleep Temp
Low Temp
Error Alarm
Ready Alarm
Pass. Lock
Password****
Initial Reset
Initial value
℉
*
OFF
30 min.
Normal
1 sec.
ON
6 min.
390
℉
(200
℃
)
270
℉
(150
℃
)
ON
ON
OFF
-
Value
℃
/
℉
OFF / ON
30 to 60 min.
Normal / Timer
1 to
5 sec.
OFF / ON
1 to 29 min.
390 to 570
℉
(200 to 300℃)
54 to 270
℉
(30 to 150
℃
)
ON / OFF
ON / OFF
ON (Lock / Partial) / OFF (Unlock)
“ABCDEF”
Select three letters
℃
/
℉
/ Cancel
6. PARAMETER SETTING
Press and hold any one of
the three control buttons while
turning on the power switch.
①
②
●
PARAMETER SETTINGS
Press and hold any one of the three control buttons, and turn on the power switch to
display the parameter setting screen. The following parameters can be set:
* For USA.
** Timer can be set when ShutOff / Auto Sleep is set to
“
ON
”
.
*** Vacuum Time is displayed when Vacuum Mode is set to
“
Timer
”
.
****Password is displayed when Password Lock is set to
“
Lock
”
or
“
Partial
”
.
14
●
Temp Mode
1. Move the cursor to select “Temp Mode”.
After selecting, press <ENT>.
Select the temperature mode from Celsius or Fahrenheit.
2. ℃ and ℉ will be switched alternately
if you press the <
↑
> or <
↓
> button.
3. Return to parameter setting display
if you press the <ENT> button after
setting.
●
ShutOff Set
1. Move the cursor to select “ShutOff Set”.
After selecting, press <ENT>.
Select whether you will activate the auto shutoff function. When the auto shutoff
function is set to on and no operation is performed for constant time after the handpiece
is set in the iron holder, the buzzer sounds three times and the auto shutoff function
will be enabled.
2. ON and OFF will be switched alternately
if you press the <
↑
> or <
↓
> button.
3. Selecting “ON” allows you to make the
setting for “Timer”.
(Default is 30 minutes.)
<↑>
<↓>
<ENT>
T e m p M o d e
S h u t O f f S e t
V a c u u m M o d e
゚ F
O F F
NOR
<↑>
<↓>
<ENT>
T e m p M o d e S e t
゚ C
<↑>
<↓>
<ENT>
T e m p M o d e
S h u t O f f S e t
V a c u u m M o d e
゚ F
O F F
NOR
<↑>
<↓>
<ENT>
S h u t O f f S e t
S h u t O f f
T i me r
O F F
30
m
Select
“OFF”
Select
“ON”
4. When setting “Shut Off” to “ON”,
the area for “Timer” flashes.
5. Press the <
↑
> or <
↓
> to set the desired
figure.
6. Pressing the <ENT> button after this change
makes the set time stored in the internal memory.
<↑>
<↓>
<ENT>
S h u t O f f S e t
S h u t O f f
T i me r
ON
0
m
<↑>
<↓>
<ENT>
T e m p M o d e
S h u t O f f S e t
V a c u u m M o d e
゚ F
ON
NOR