![background image](http://html1.mh-extra.com/html/hakko-electronics/fn-1201/fn-1201_instruction-manual_3286775011.webp)
9
7-4 Support for new models
In order to add support for a new model to the connection box, it is necessary to install the command
support file for that model.
1.
With the connection box connected to the PC, start the Command Support File Installation
Application.
2.
Select the file to be installed and click
[Send]
.
3.
Press the Reboot button of the connection box more than three seconds.
4.
Check that the Command Support File Installation Application shows the installed model and shut
down the application.
CAUTION
Depending on the operating status of the connected equipment, the contents of each
kind of file sent to the connection box will not be applied to the equipment in some
cases.
Whether or not the contents have been applied should be checked each time.
When the power supply is turned off without pushing the reboot button, the connection
box may not work normally.
7-5 LED status
initializing
Green LED blinking at 0.3 seconds interval
Normal operation
Green LED blinking at 2 seconds interval
Starting while pressing
the reset button
Red LED lights for 1 second, and changes to LED status of normal
operation (Green LED blinking at 2 seconds interval).
abnormal status
Red LED blinking at 0.3 seconds interval
When the LED showed abnormal status, please contact the sales office or distributor.