7
Controls and displays
Controls
The front panel of the HAKKO FM-205 has four
controls.
.........End of sequence signal (terminates a
phase of a data entry mode). When
pressed for less than one second,
displays settings already stored.
.........Initiates a data entry mode.
.........Increases the displayed value.
...Decreases the displayed value.
The HAKKO FM-2027 and the MODEL FM-
2024 can be connected to the HAKKO FM-205
Station.
The lamp on the grip operates as follows.
In use ................ Lights
Sleep mode ....... Blinks slowly
Off mode ........... Off
Error .................. Blinks quickly
Operation
1. Turn the power switch ON.
2. By default, when the set temperature is
reached, the buzzer sounds, indicating that
the unit is ready.
The heater lamp on the front panel starts
blinking.
5. OPERATION
Displays
The HAKKO FM-205 has a three-digit display
element.
Depending on the selected mode, it will display:
●
Sensor temperature (of the iron tip)
●
Data entry:
Selected quantity (See the data entry
procedures.)
●
Temperature scale:
ºC or ºF, depending on selection
●
Error detection (See ERROR MESSAGES.)
An audible buzzer is provided to alert the
operator:
●
When the station has reached the set
temperature, the buzzer will sound once.
(Default setting)
●
When the low temperature threshold has been
crossed, the buzzer will sound continuously.
This buzzer will shutoff when the sensed
temperature returns to the acceptable range.
●
When a foreign substance, an incompatible
tip, or the soldering end of the tip is inserted
into the HAKKO FM-2027, the display will
blink and the buzzer will sound continuously.
●
When the auto-power shutoff function is
activated and power to the heater is shut off,
the buzzer sounds three times.
CAUTION
By default, the temperature is set to 350ºC (660ºF).
You can confirm the set temperature by pressing the
button. The set temperature will be displayed for two
seconds.
CAUTION
When not in use, set the iron in the iron holder.
button
button
button
button
Receptacle