6
4. 4. Connect the DCB to the shop
air supply/compressor.
Use only filtered air to eliminate
the probability of dust, water,
and oil content from fouling the
mechanism.
Adjust the pressure to 490 kPa
(5.0 kgf/cm
2
) with the regulator
while allowing air to flow by
pressing the button (or pulling the
trigger) on the handpiece.
CAUTION
If you attempt to adjust the pressure
without allowing air to flow, or if the
tube size is not as specified, the
suction capability will decrease.
Ensure that the regulator shows less
than 882 kPa (9.0 kgf/cm
2
) when the
trigger is turned OFF. If pressure equal
to or higher than this value is applied,
damage may result.
5. Turn ON the power
Ensure that the power switch is
OFF before inserting the AC plug.
CAUTION
Be sure to ground this product as it is
ESD safe by design.
Turn the power switches ON as
follows: First, the DCB; second,
the soldering station. Unless
the DCB is turned on first, an
error message will appear since
the desoldering iron remains
disconnected.
Typical
interconnections
DCB
Tube
Use a tube with inner diameter of 0.16
in. (4 mm) minimum.
Use length of 9.8 ft. (3 m) maximum.
Joint
Threaded portion
outside diameter
ø0.24 in. (ø6 mm)
Regulator
Adjust to 490 kPa
(5.0 kgf/cm
2
)
Air filter
Removes foreign
matter, dust, oil
content, and water
content
Compressor
CAUTION
Be sure to use an air filter. Foreign matter in the piping
or the air supply can jam the solenoid valve, causing a
failure.