![background image](http://html1.mh-extra.com/html/hakko-electronics/941/941_instruction-manual_3333113007.webp)
●
●
●
●
●
Factory settings
The Hakko 941 comes from the factory with the
following values preset:
Temperature scale
Auto power shutoff
Low temperature alarm setting
Resetting the supervisor/
operator control setting
Set temperature
Celsius
disabled
150
˚
C.
4 0
350
˚
C.
6
●
●
●
●
●
Control card
Each Hakko 941 comes with a small card, which
inserts in the control slot in the front of the unit.
This card is used when entering data for the
process control functions. Any Hakko 941 card
can be used with any Hakko 941 soldering
station.
Using the control card
The control card is used when a value is to be
changed or data are to be entered. The Hakko
941 will operate normally with the card inserted.
If power is turned on with the card inserted, the
station will heat to the temperature set before
the card was inserted.
●
●
●
●
●
Changing the temperature
setting
Example:
350° to 400°
1. Insert the control card into the slot in the
front of the unit.
• The
hundreds
digit will begin to flash,
indicating that the unit is in the TEM-
PERATURE SET mode and data may be
entered.
2. Entering the
hundreds
digit
• Press the
or
button to set the
desired figure.
Only 2, 3, or 4 can be
selected. (In °F mode, 4, 5, 6, 7, or 8 can
be selected).
When the desired figure is displayed,
press the
button to enter. The
tens
digit
will begin to flash.
CAUTION:
The card must be inserted into the card slot in the correct
direction. The heater is off while you are setting the tem-
perature.
Press the button once.
Insert the card.
Press the or button.