MANOK plus
Technical data
Order h49 7144.907-333
25
3.6.4 Diagram of actuating torque to actuating force
Scan sample 1:
At an actuating torque of
70 Nm, the axial tension-
ing force for size 65 is 31
kN.
Scan sample 2:
At a required axial actuat-
ing force of 20 kN, an ac-
tuating torque of 45 Nm
must be applied for size
65.
A
Size 65
3.7 Operating conditions
Indication
Value
Unit
Ambient temperature range
15 - 65
°C
Workpiece temperature
≤ 80
°C
Humidity
≤ 80
%
Table 3:
Operating conditions
3.8 Type designation
The type designation is on the product and it includes the
following indications:
Manufacturer
Product designation
ID number [marked with a # symbol]
Build year
Maximum actuating force
𝐹
𝑎𝑥 𝑚𝑎𝑥
[𝑘𝑁]
Maximum clamping force
𝐹
𝑟𝑎𝑑 𝑚𝑎𝑥
[𝑘𝑁]
Maximum actuating torque
𝑀
𝑚𝑎𝑥
[𝑁𝑚]