Remote Control Features And Settings
Remote Control
1. Power-up and Show all:
After inserting the batteries the display will show all symbols for
3 seconds. The remote will then enter clock set mode. Use +/- to
adjust the clock. Press CONFIRM when done. If no action is taken
within 10 seconds then the remote will exit set mode. See section
22 for clock setting instruction.
2. ON/OFF Button:
Press the ON/OFF button on the remote control to start the unit.
3. SMART Button:
(1) In SMART mode the air conditioner will automatically switch
between Cool, Heat, or Fan to maintain set temperature.
(2) When the fan is set to AUTO the air conditioner automatically
adjusts the fan speed according to room temperature.
(3) The SMART button also works to power the unit on and off.
4. COOL Button, HEAT Button and DRY Button:
(1) In COOL mode ,the unit operates in cooling. When FAN is set
to AUTO,the air conditioner automatically adjusts the fan speed
according to room temperature. COOL will be displayed during
COOL mode.
(2) In HEAT mode ,warm air will blow out after a short period of
the time due to cold-air prevention function. When FAN is set to
AUTO, the air conditioner automatically adjusts the fan speed
according to room temperature. HEAT will be displayed during
HEAT mode.
(3) DRY mode is used to reduce humidity.In DRY mode, when room
temperature becomes lower than temp. 2°F,unit will run
intermittently at LOW speed regardless of FAN setting. DRY will be
displayed during DRY mode.
5. FAN SPEED Button:
Fan speed selection
Press FAN SPEED button. For each press,fan speed changes as
follows:
The air conditioner fan will run according to the displayed fan
speed. When FAN is set to AUTO,the air conditioner automatically
adjusts the fan speed according to room temperature.
6. TEMP. +/- Buttons:
Temp+ Every time the button is pressed,the temperature setting
increases. Temp- Every time the button is pressed,temperature
setting decreases. The operating temperature range is 60°F -86°F
(16°C-30°C).
7. Quadrant Control
(Available on some models):
This setting allows the vertical airflow to be adjusted
individually on each side of the unit.
(1) Initial default positions.
(2) Press the Quadrant Control button to select the quadrant.
Each button press will select as shown below:
(3) Once desired quadrant is selected then use the Vertical Swing
button to set the direction of airflow. See section 9.
8. Vertical SWING Button:
Air Flow Direction Adjustment
Press the SWING UP/DOWN button to choose the position of the
vertical airflow louvers.
Status display of air flow
9. Horizontal SWING Button:
Press the SWING LEFT/DOWN button to choose the position of
the hortzontal airflow louvers.
Status display of air flow
6
5
16
1
Mode
SMART
HEAT
COOL
DRY
FAN
Initial
TEMP.
24°C
(75°F)
24°C
(75°F)
24°C
(75°F)
24°C
(75°F)
Setting
temperature
is not
showed.
Mode
SMART
HEAT
COOL
DRY
FAN
Initial
Fan
Speed
AUTO
LOW
HI
AUTO
LOW
LOW
MED
HI
LOW, MED and HIGH
indicator cycles.
AUTO FAN SPEED
SMART
HEAT
COOL
DRY
FAN
Selected
Quadrant
Show all
Show
all
Show
all
Show
all
Show all
Vertical
SWING
Angle
Position
3
Position
5
Position
3
Position
3
Positon
3
COOL/DRY
HEAT
Auto
Auto
1
2
3
6 5
4
COOL/DRY/HEAT:
Auto
1 2 3
6
5
4