34

Name

Blood Bank Refrigerator

Model

HXC-358

HXC-358B

Exterior dimensions

 (W x D x H) (mm)

720x690x1730

Interior dimensions

 (W x D x H) (mm)

620x490x1160

Eff ective volume

358L

Door

Glass door with electric heat

Insulation

CFC-Free foamed-in-place urethane

Compressor

High Quality Hermetically sealed compressor

Shelves / Drawer

5 shelves / 20 baskets

5 Drawers

Load

Max:25kg per shelf

Refrigerating Method

Forced convection cooling

Exterior / Interior

Scratch resistant painted steel / Stainless steel

Condenser/Evaporater

Fin tube type

Temperature Control

Microprocessor controlled

Refrigerant

R134a 420g

Interior light

LED 3W

Net weight

158kg

165kg

Temperature range

4±1

Voltage

220V-240V~/50Hz/60Hz

Rated power / current

460W/3.0A

Noise Level

43dB(A)

Foaming Agent

HFO-1233zde

Climate Type

ST

Anti-shock Safety 

Classifi cation

I

Power connection type

Y

USB function / temperature 

recorder

Optional / Standard

Alarm system

High-low temperature alarm, sensor fault alarm, power failure alarm, 

low battery alarm and door opening alarm

Battery duration for alarm 

system

48 hours (when battery is fully charged)

Rechargeable battery

DC12V Rechargeable lead-acid battery

Note: Climate Type ST means the  temperature is 18 - 38

,the relative humidity is up to 85%.Due 

to continuous improvements, technical information on your refrigerator may be diff erent from herein 
published.

7

•Ambient temperature: 18

 to 38

 with exception of HXC-106/1308/1308B at 16

 to 32

. Range 

of 18

 to 25

 is ideal.

•Ambient humidity: below 85% RH .
•Avoid dusty and unstable areas for installation.
•Avoid mechanical swing or vibration. 
•The refrigerator shall operate at an altitude lower than 2000m. 
•Input voltage: Within rated voltage ±10%.

The installation site shall meet following requirements for normal operation and best performance of 
refrigerator:
•Do not install the refrigerator in a narrow and confi ned space  as heat may be trapped to increase 
ambient temperature. Additionally, a unit should not be installed in a space where the entry door way 
is low to prevent an easy maneuver of the unit for maintenance and operation.
•The ground at the installation site shall be solid and fl at.
•The fl oor for the installation site should be solid and fl at. It should also be well ventilated and free 
from direct sunshine.
•The power outlet for  the  refrigerator must be a  dedicated  power outlet. The  power  plug must  be 
plugged in to the outlet securely.
•Do not twist or jam the power cord.
•If the power cord needs to be extended, the cross section area of the conductor in the extended line 
should be no less than 3 squared millimeters and no longer than 3 meter.
•Inspect the  operating  voltage  range  before operation. If  the  voltage  supply  is  unstable,  install  a 
voltage stabilizer of 4000W or greater to ensure the supply voltage is within 10% of the rated voltage 
supply.
•The refrigerator must be grounded reliably.
•Check the integrity of the socket ground before power up. If it is not grounded appropriately, repair 
the wiring before installing the unit.
•If  the  socket  is  not  provided  with  grounding  wire,  a  new  one  shall  be  installed  by  engineering 
technician.

•Refrigerator  units  are  not  permitted  to  operate  outdoors.  Rough  condition  and 
rainwater can cause electrical issues and hazardous conditions.
•It is prohibited to install the refrigerator outdoors. Electric leakage or shock may be 
caused if the refrigerator gets wet by rainwater.

•Do  not  ground  the  refrigerator  through  gas  lines,  water  lines,  telephone  lines,  or 
lighting rods as these devices may cause electric shock and danger.
•The power  plug  and  outlet  should  be  located  in  a  place where  it  can be  accessed 
easily and immediately in case of an emergency. Air vents must be free of obstruction.

Product Installation

Installation environment

Caution

Installation site

Warning

Summary of Contents for HXC-106

Page 1: ......

Page 2: ...guidelines 5 Product Feature 6 Product Installation 7 Component Names Control Panel 12 Application method 16 Display and alarm 22 Cleaning and Maintenance 26 FAQ 28 Refrigeration Schematic Circuit Di...

Page 3: ...en replacing the light from the power source to avoid electric hazards Warning 1 Unauthorized opening of the top cover of the control cabinet is prohibited to avoid damages to the parts inside or inju...

Page 4: ...it is equipped with a 16A or 13A power plug Do not remove the ground pin of the power plug under any circumstances Make sure the plug is securely plugged into the power outlet to prevent re The power...

Page 5: ...harmful or radioactive particles If the refrigerator is to be decommissioned unplug the power cord to avoid electric shock current leakage or re caused by aged power lines If the refrigerator is left...

Page 6: ...accelerate the defrosting process other than those recommended by the manufacturer Do not damage the refrigerant circuit In order to reduce ammability HAZARDS the installation of this equipment shall...

Page 7: ...e as the temperature in the center of the refrigerator The cabinet temperature will gradually reach an equilibrium state Only clean the unit with light soapy water Never use brushes acids gasoline soa...

Page 8: ...lood bank refrigerator provided to you may be a little di erent from the gure in the manual due to product improvement The manual may be subject to changes without further notice 35 Name Blood Bank Re...

Page 9: ...frigerator Do not install the refrigerator in a narrow and con ned space as heat may be trapped to increase ambient temperature Additionally a unit should not be installed in a space where the entry d...

Page 10: ...14 1055 Interior dimensions W x D x H mm 460 370 950 430 350 830 E ective volume 158L 106L Door Glass door with electric heat Insulation CFC Free foamed in place urethane Compressor High Quality Herme...

Page 11: ...mal operation 6 Installation of the Handle Handle installation of products shall be conducted in the following steps Orient the handle with the hole downwards Align the handle and handle guide on door...

Page 12: ...ce the unit is powered up the audible alarm is turned on Turn on the battery switch and press the buzz cancel button to silence the alarm Visual alarm continues until the temperature in the measuremen...

Page 13: ...oducts Do not load in too much warm product at one time Overloading the refrigerator will reduce the system s expected life Therefore product and samples should be placed into the refrigerator in batc...

Page 14: ...g Temperature recorder Optional for HXC 158 Blood storage basket or drawer Shelf USB port optional Interior light Temperature measurement box Caster Door ajar alarm switch Air filter grille 29 Refrige...

Page 15: ...perature is too high Air duct is blocked Unit seems to emit too much noise Check the installation of the unit to make sure the unit does sit on a solid oor without vibration Whether certain part of th...

Page 16: ...temperature recorder is standard on the product optional for HXC 158 If additional chart paper is needed please contact Haier Biomedical The ordering cycle is 1 2 months Consult us by phone for detail...

Page 17: ...e after sales service personnel Cleaning and Maintenance Warning Clean the refrigerator Replace the illumination light Condensate evaporator is located in the back of the refrigerator Remove the 2 scr...

Page 18: ...tem is in a n alarm mode press the Buzzer Cancel key on the display board and the audible alarm is silenced temporarily Remote alarm condition will not be a ected After 30 minutes if the alarm conditi...

Page 19: ...timely manner to protect the samples When there is a fault in the battery E5 will show after pressing Alarm test Check the battery charge switch to make sure it is in the On position If it is O turn...

Page 20: ...ly Buzzing Alarm light ashes Display actual temperature Remote alarm contacts reverse and audible alarm starts Remote alarm can be cancelled after pressing Silence button If the alarm condition persis...

Page 21: ...y battery is low ashing of LED indicator lamp on the recorder indicates that the battery needs to be changed Maintenance and change of emergency battery of the recorder When the green LED of recorder...

Page 22: ...lay panel ashes USB which indicates the data are now exporting and not nished yet After 5 seconds the display will return to the temperature mode If the display shows ALL indicating the data export pr...

Reviews: