![Haier HXC-106 Operation Manual Download Page 6](http://html1.mh-extra.com/html/haier/hxc-106/hxc-106_operation-manual_4727072006.webp)
4
The angle of inclination shall not be greater than 45° when the refrigerator is handled or moved.
Be aware of the danger of tripping when working with the refrigerator to avoid managing the unit
or personal injury.
Do not use the door knob to move the unit to prevent refrigerator damage or personnel injury.
Do not damage the refrigeration line.
Position the refrigerator to make sure the power plug is accessible.
The refrigerator must be placed on a solid and fl at surface; otherwise there might be excessive
vibration or noise.
The refrigerator can be operated by children aged 8 and older and persons with disability if they
are supervised and they understand the potential hazards involved. Children should not play with
the appliance. Children should not be involved in cleaning or maintaining the unit without proper
supervision.
If the power supply cord is damaged, it should be replaced by a qualifi ed technician to avoid a
hazard condition.
Keep the ventilation openings of the refrigerator clear of obstruction.
If the unit is to be discarded, remove the door and leave the shelves in place. This will reduce
the possibility of danger to children. Flammable materials must be disposed of by professionals.
Keep all ventilation openings in the enclosure or, in the structure for building-in, clear of
obstruction.
Do not use mechanical devices or other means to accelerate the defrosting process, other than
those recommended by the manufacturer.
Do not damage the refrigerant circuit.
In order to reduce fl ammability HAZARDS the installation of this equipment shall only be carried
out by a suitably qualifi ed person.
37
Name
Blood Bank Refrigerator
Model
HXC-1308
HXC-1308B
Exterior dimensions
(W x D x H) (mm)
1440x925x1980
Interior dimensions
(W x D x H) (mm)
1320x700x1500
Eff ective volume
1308L
Door
Glass door with electric heat
Insulation
CFC-Free foamed-in-place urethane
Compressor
High Quality Hermetically sealed compressor
Shelves / Drawer
12 shelves / 48 baskets
12 Drawers
Load
Max:30kg per shelf
Refrigerating Method
Forced convection cooling
Exterior / Interior
Scratch resistant painted steel / Stainless steel
Condenser/Evaporater
Fin tube type
Temperature Control
Microprocessor controlled
Refrigerant
R134a 490g
Interior light
LED 5W
Net weight
310kg
335kg
Temperature range
4±1
℃
Voltage
220V-240V~/50Hz
Rated power / current
850W/4.2A
Noise Level
45dB(A)
Foaming Agent
HFO-1233zde
Climate Type
N
Anti-shock Safety
Classifi cation
I
Power connection type
Y
USB function / temperature
recorder
Standard / Standard
Alarm system
High-low temperature alarm, sensor fault alarm, power failure alarm,
low battery alarm and door opening alarm
Battery duration for alarm
system
48 hours (when battery is fully charged)
Rechargeable battery
DC12V Rechargeable lead-acid battery
Note: Climate Type ST means the temperature is 18 - 38
℃
.Due to continuous improvements,
technical information on your refrigerator may be diff erent from herein published.
Summary of Contents for HXC-106