30
3) Function setting
Picture 20
Press “FUNCTION” icon to enter the function setting interface, shown in Picture 20. In this interface, you can turn on or off
some common functions, and adjusting its working hours. In this interface, you can set following functions.
System functions of user setting
Function
Parameter Range
Default
Remarks
Sterilization
Operation
On/Off
Off
When the unit is sterilizing,
the sterilization icon is flashing
displayed in the main interface
Week
Monday ~ Sunday
Monday
Time
00:00~24:00
23:00
Temp.
50°C~75°C
75°C
ECO (economy)
Mode
Operation
On/Off
Off
It’s only valid at heating mode.
During the energy-saving
operation of the unit, the outlet
water temperature is
△
T lower
than the set temperature.
Time
24 hours
22:00~07:00
△
T
(Difference between energy
saving temperature and
actual temperature.)
-15°C~0°C
-5°C
Holiday Mode
Operation
On/Off
Off
To save energy, a holiday
period may be set to lower the
temperature during the period.
Date
Start date ~ End date Current date~
Current date
Setting Temp. of Zone1
0°C~30°C
15°C
Setting Temp. of Zone2
0°C~30°C
15°C
Quiet
Operation
On/Off
Off
To operate quietly during the
preset period.
Time1
Start time ~ End time Current time~
Current time
Time2
Start time ~ End time Current time~
Current time
Turbo
Operation
On/Off
Off
Turbo mode is use to increase the
capacity of heat pump to achieve
higher target temperature.
Timer
30min/60min/90min/
Continuous
60min
Fast DHW
On/Off
Off
/
DHW Priority
On/Off
On
No matter what mode the unit is
in, the domestic hot water shall be
heated first.
Dry Concrete of Zone1
On/Off
Off
/
Dry Concrete of Zone2
On/Off
Off
/
IDU Antifreeze Protection
On/Off
On
/
IDU Antifreeze Temp.
0~15°C
5°C
/
Operation instructions for controller