10
Installation Instructions
A. Select the Best Installation Location
The unit must be installed indoors, and the requirements are as follows.
• The indoor unit must be installed on a vertical wall.
•
The mounting wall must be even and nonflammable, it must be strong and solid enough to hold the unit and prevent it
from vibration.
• There should not be any heat source or steam near the indoor unit.
•
A place where freezing, leakage of corrosive gas and flammable gas or dust, carbon fibre or flammable particals
suspension will never occur around the unit.
• A place where the ventilation is enough.
•
A place where drainage can be easily done (e.g. Utility room).
• A place where the operation noise will not cause discomfort to the user.
•
Ensure there is enough clearance around the unit from wall, ceiling, or other equipment for service and air circulation.
• The recommended minimum installation height for indoor unit is 1150mm.
Note:
•
If there's any possibility of small animals entering the unit from pipe outlet, then block it.
• Do not install the unit outdoors. The unit is designed for indoor installation only.
•
When install electrical equipment at wooden building of metal lath or wire lath, according to electrical facility technical
standard, no electrical contact between equipment and building is allowed.
200mm
200mm
200 mm
1150mm
B. Fix the Installation Plate
• The distance between the center of installation plate and left or right wall shall be more than 375 mm.
• The distance from ground to the lower edge installation plate
Ⅰ
should be more than 1956mm.
• Mount the installation plate
Ⅰ
horizontally by aligning the marking thread and check with a level gauge.
• The installation plate
Ⅰ
shall be fixed to the wall with 3 bolts of size M8.