Indoor unit

Fixing the indoor unit body

[Other direction piping]

Indoor/outdoor electric cable and drain hose must be bound with refrigerant piping by protecting tape.

Cut away, with a nipper, the lid for piping according to the piping direction and then bend the pipe according

to the position of wall hole. When bending, be careful not to crash pipes.

Connect beforehand the indoor/outdoor electric cable, and then pull out the connected to the heat insulation

of connecting part specially.

Hang surely the unit body onto the upper notches of the

mounting plate. Move the body from side to side to verify

its secure fixing.

In order to fix the body onto the mounting plate,hold up

the body aslant from the underside and then put it down

perpendicularly.

1. Insert the drain hose into the dent of heat insulation materials of indoor unit.

2. Insert the indoor/outdoor electric cable from backside of indoor unit, and pull it out on the front side, then

    connect them.

3. Coat the flaring seal face with refrigerant oil and connect pipes.

    Cover the connection part with heat insulation materials closely, and make sure fixing with adhesive tape

4

Heat insulation

material

Piping

Unloading of indoor unit body

When you unload the indoor unit,please use your hand to arise
the body to leave agraffe,then lift the bottom of the body outward

slightly and lift the unit aslant until it leaves the mounting plate.

agraffe

mounting plate

Lid for right piping

Lid for under piping

Drain hose

Lid for left piping

mounting plate

Drain hose

Pipe clip

Indoor/Outdoor

electrical connecting

Summary of Contents for HSU-18CRA03-T

Page 1: ...Drain hose Heating insulating material Piping hole cover Arrangement of piping directions Rear left Rear right Left Below Right The marks from to in the figure are the parts numbers The distance betw...

Page 2: ...ptacle with enough space around Refer to drawings Place where the distance of more than lm from televisions radios wireless apparatuses and fluorescent lamps can be left In the case of fixing the remo...

Page 3: ...ticle When the mounting plate is first fixed for the position of wall hole Fix to side bar and lintel a mounting bar Which is separately sold and then fasten the plate to the fixed mounting bar Make a...

Page 4: ...ody aslant from the underside and then put it down perpendicularly 1 Insert the drain hose into the dent of heat insulation materials of indoor unit 2 Insert the indoor outdoor electric cable from bac...

Page 5: ...h the wiring cover Note When connecting the cable confirm the terminal number of indoor and outdoor units carefully If wiring is not correct proper operation can not be carried out and will cause defe...

Page 6: ...wiring is not correct proper operation can not be carried out and controller may be damaged If the drain elbow is used please attach it as figure Note Only for heat pump unit Drawing for the installat...

Page 7: ...ing to the following list Piping length Additional amount 5m 7m No need 40g 10m 100g for 9k 12k 18k Push the air out of the indoor unit and piping as followes 1 Remove the valve cap on 2 way valve in...

Page 8: ...pan of the indoor unit and confirm that drainage is carried out surely to outdoor In case that the attached drain hose is in a room please apply heat insulation to it without fail Please kindly expla...

Reviews: