background image

3

Indoor unit

Outdoor unit

Power cable:

HSU-07HVA103/R2(DB)
HSU-09HVA103/R2(DB)
HSU-12HVA103/R2(DB)

4G1.5mm

2

HSU- 09HA103/R2(DB)
HSU- 12HA103/R2(DB)

Indoor unit

Outdoor unit

power

1(N)

L

N

2(L)

3(C)

HFU-09HA03/R2(DB)

Indoor unit

4G0.75mm

2

)

C(

3

)

N(

1

)

L(

2

)

C(

3

)

N(

1)

L(

2

^

POWER

Power cable:     3G1.5mm

2

HFU-12HA03/R2(DB)

Power cable:     3G1.5mm

2

4

Outdoor unit

Indoor unit

HSU-09HEA03/R2(DB)-I
HSU-12HEA03/R2(DB)-I

Outdoor unit

Indoor unit

A

B

Outdoor unit

Indoor unit

A

B

A

B

Outdoor unit

Indoor unit

Oil trap

Outdoor unit

Install according to

Drawing for the installation of indoor and outdoor units

To bend  a  pipe, give the roundness as large as possible not to crush the pipe ,

ƽ

and the bending radius should be 30 to 40 mm or longer.

Connecting the pipe  of  gas side first makes  working easier.

ƽ

The connection pipe is specialized for R410A.

ƽ

Use the same method on indoor unit. Loosen the screws on

ƽ

terminal block and

insert the plugs fully into terminal block, then tighten the screws.

Insert the cable according to  terminal number in the same manner as the indoor
unit.

ƽ

If wiring is not correct, proper operation can not be carried out and controller
may be damaged.

ƽ

Fix the cable with a clamp.

ƽ

Installation of Outdoor Unit

Half union

Flare nut

Torque wrench

CAUTION

Be careful that matters, such as wastes of sands, etc. shall not enter the pipe.
The standard pipe length is 5m. If it is over 7m, the function of the unit will be
affected. If the pipe has to be lengthened, the refrigerant should be charged,

according to 20 g/m. But the charge of refrigerant must be conducted by profes-

sional air conditioner engineer. Before adding additional refrigerant, perform air
purging from the refrigerant pipes and indoor unit using  a  vacuum pump,then

Spanner

Forced fastening without careful centering may
damage the threads and cause a leakage of gas.

Max.Elevation: Amax=10m

In case the elevation A is more

than 5m, oil trap shoud be

installed every 5~7m

Max. Length: Bmax=15m

In case the pipe length  B  is

more than 7m, the refrigerant

should be charged, according

to 20 g/m.

Connection of pipes

charge additional refrigerant.

Connection

Pipe Diameter( )

Fastening torque

Liquid side6.35mm(1/4")

18N.m

Liquid/Gas side9.52mm(3/8")

42 N.m

Gas side 12.7mm(1/2")

55N.m

Gas side 15.88mm(5/8")

60 N.m

Φ

Outdoor unit

HUM07HA03/R2(DB)
HUM09HA03/R2(DB)
HUM12HA03/R2(DB)

1. If the supply cord is damaged, it must be replaced by the manufacturer or its

service agent or a similar qualified person. The type of connecting wire is

H05RN-F or H07RN-F.

2. If the fuse on PC board is broken please change it with the type of 

3. The wiring method should be in line with the local wiring standard.
4. After installation, the power plug should be easily reached.

5.  A  breaker should be incorporated into fixed wiring. The breaker should be

all-pole switch and the distance between its two contacts should be not less
than 3mm.

T.3.15A/250VAC (Indoor), T.25A/250VAC (Outdoor).

HUM09HB03/R2(DB)
HUM12HB03/R2(DB)

HUM12HC03/R2(DB)

HUM09HC03/R2(DB)

HSU-09HEA03/R2(DB)
HSU-12HEA03/R2(DB)

HSU-12HEA03/R2(DB)-A

Summary of Contents for HSU-12HEA03

Page 1: ...age without fail The power source is the same as the corresponding name plate Install an exclusive branch circuit of the power A receptacle shall be set up in a distance where the power cable can be r...

Page 2: ...e front side then connect them 3 Coat the aring seal face with refrigerant oil and connect pipes Cover the connection part with heat insulation materials closely and make sure xing with adhesive tape...

Page 3: ...cted If the pipe has to be lengthened the refrigerant should be charged according to 20 g m But the charge of refrigerant must be conducted by profes sional air conditioner engineer Before adding addi...

Page 4: ...conditio ner according to the amount marked on the name plate Please do not let other cooling medium except speci ed one R410A or air enter into the cooling circulation system Otherwise there will be...

Page 5: ...de la unidad y que no ampli que el ruido y las vibraciones Seleccione un lugar en el que los residuos y el viento generado por la unidad no cause una molestia a los vecinos Coloque la unidad en un lug...

Page 6: ...gerante utilizando cinta protectora Entubaci n en otra direcci n Corte con una cuchilla la cubierta de entubaci n de acuerdo con la direcci n de entubaci n y doble los tubos de acuerdo con la posici n...

Page 7: ...so de que la elevaci n A sea superior a 5m el filtro de aceite debe instalarse cada 5 7 m Longitud m x Bm x 15m En caso de que la longitud del tubo B sea superior a 7m deber cargarse el refrigerante a...

Page 8: ...e contiene el producto de f brica 2 La cantidad de refrigerante adicional cargada durante la instalaci n y 1 2 La carga total de refrigerante en la etiqueta de refrigerante suministrada con el product...

Page 9: ...o dell unit dove le vibrazioni ed il rumore non siano aumentati Luogo dove l aria di scarico ed il rumore non provocano disturbo ai vicini di casa Luogo dove sia disponibile una distanza contrassegnat...

Page 10: ...la direzione della stessa e piegarla in base alla posizione del foro sulla parete Quando si piega prestare attenzione e non spaccare i tubi Connettere prima il cavo elettrico interno esterno quindi es...

Page 11: ...le tubature del refrigerante e dall unit interna usando una pompa a vuoto poi caricare il refrigerante A B A B A B AVVERTENZA Unit interna Unit da esterno Unit da esterno Trappola per l olio Unit inte...

Page 12: ...ante forni ta col prodotto L etichetta compilata deve essere attaccata accanto alla porta di caricamento del prodotto es all interno del coperchio con il valore di arresto A Questo prodotto contiene g...

Page 13: ...ez un emplacement capable de supporter l unit o les vibrations et le bruit n augmentent pas S lectionnez un emplacement o le vent et le bruit ne risquent pas de g ner les voisins Choisir un endroit da...

Page 14: ...eures ext rieures et le tuyau de vidange doivent tre x s au tuyau de r frig rant avec un ruban protecteur Tuyauterie dans une autre direction A l aide d une pince d coupez le couvercle pour la tuyaute...

Page 15: ...A B A B A B AVERTISSEMENT Unit int rieure Unit ext rieure Unit ext rieure Pi ge dl huile Unit int rieure Unit ext rieure Unit int rieure Hauteur max Amax 10m Si la hauteur A d passe les 5m installez...

Page 16: ...an te Merci de remplir l encre ind l bile 1 la charge de r frig rant standard de l appareil 2 la quantit suppl mentaire de r frig rant charg e sur place et 1 2 charge totale de r frig rant sur l tique...

Reviews: