background image

Indoor unit

Fix to side bar and lintel  a  mounting bar, Which is separately sold, and then

ƽ

fasten the plate to the fixed mounting bar.

Refer to the previous article, “ When the mounting plate is

ƽ

position of wall hole.

Make a hole of 60 mm in diameter, slightly descending to outside the wall.

ƽ

Install piping hole cover and seal it  off with putty  after installation

ƽ

When the mounting plate is first fixed

1. Carry out, based on the neighboring pillars or lintels, a 

to be fixed against the wall, then temporarily fasten the plate with one steel nail.

2. Make sure once more the proper level of the plate, by hanging a thread with a 

weight from the central top of the plate, then fasten securely the plate with the
attachment steel nail.

3. Find the wall hole location A using a measuring tape

When the mounting plate is fixed side bar and lintel

Fitting of the Mounting Plate and Positioning of the wall Hole

Lid for right
piping

Lid for under piping pipe

Fix with adhesive tape

Lid for left piping

Indoor/outdoor electric cable and drain hose must be bound with refrigerant

ƽ

piping by protecting tape.

[ Other direction piping ]

Cut away, with a nipper, the lid for piping according to the piping direction and

ƽ

then bend the pipe according to theposition of wall hole. When bending, be

careful not to crash pipes.

Connect beforehand the indoor/outdoor electric cable,

ƽ

and then pull out the

connected to the heat insulation of connecting part specially.

proper leveling for the plate

first fixed “, for the

Making a Hole on the Wall and Fitting the Piping Hole Cover

Drawing of pipe

Installation of the Indoor Unit

[ Rear piping ]

Draw pipes and the drain hose, then fasten them with the adhesive tape

ƽ

[ Left

Left-rear piping ]

In case of left side piping, cut away, with a nipper, the lid for left piping.

ƽ

In case  of  left-rear piping, bend the pipes according to the piping direction to

ƽ

the mark of hole for left-rear piping which is marked on heat insulation materials.

1. Insert the drain hose into the dent of heat insulation materials of indoor unit.

2. Insert the indoor/outdoor electric cable from backside of  indoor unit, and pull it

out on the front side, then connect them.

3. Coat the flaring seal face with refrigerant oil and connect pipes.

Cover the connection part with heat insulation materials closely, and make sure

fixing with adhesive tape

Fixing the indoor unit body

Hang surely the unit body onto the upper notches of the

ƽ

mounting plate. Move the body from side to side to verify its
secure fixing.

In order to fix the body onto the mounting plate,hold up

ƽ

the body aslant from the underside and then put it down
perpendicularly.

Connecting the indoor/outdoor Electric Cable

Removing the wiring cover

Remove terminal cover at right bottom corner of indoor unit, then take

ƽ

  off wiring cover by removing its screws.

1. Insert from outside the room cable into left side  of  the wall

hole, in which the pipe has already existed.

2. Pull out the cable on the front side, and connect the cable

making a loop.

Note

When connecting the cable, confirm the terminal number of indoor and
outdoor units carefully. If wiring is not correct, proper operation can not

be carried out and will cause defect.

Insert the cable from the back

ƽ

side of the unit, then pull it out on the front side.

Loosen the screws and insert

ƽ

the cable ends fully into terminal block, then

tighten the screws.

Pull the cable slightly to

ƽ

make sure the cables have been properly inserted and

tightened.

After the cable connection,

ƽ

never fail to fasten the connected cable with the

wiring cover.

mounting plate

When connecting the cable after installing the indoor unit

When connecting the cable before installing the indoor unit

When you unload the indoor unit,please use 

then lift the bottom of the body outward
slightly and lift the unit aslant until it
leaves the mounting plate. 

agraffe

mounting plate

Unloading of indoor unit body

ƽ

your hand to arise the body to leave agraffe,

Remote controller (1)

R-03 dry battery (2)

Mounting plate (1)

Drain hose (1)

Ø4X25 Screw (4)

Plastic cap (4)

Drain-elbow (1)

Cushion (4)

Pipe supporting plate (1)

Accessory parts

Liquid pipe (Ø)

6.35mm(1/4”)

Gas pipe (Ø)

9.52mm(3/8”)

NOTE

˖

The thickness of the pipe must be 0.8mm at least.

Selection of pipe

2

A=145mm

30mm

A=145mm

B=

60mm

Ø

30mm

B=

60mm

Ø

Heat insulation
material

Drain hose

Piping

Pipe supporting
plate

Indoor/outdoor electric cable

Indoor side

Outdoor side

Ø60mm

Wall hole

Thickness of wall

(Section of wall hole)

 Piping hole pipe

G

Summary of Contents for HSU-12HEA03

Page 1: ...age without fail The power source is the same as the corresponding name plate Install an exclusive branch circuit of the power A receptacle shall be set up in a distance where the power cable can be r...

Page 2: ...e front side then connect them 3 Coat the aring seal face with refrigerant oil and connect pipes Cover the connection part with heat insulation materials closely and make sure xing with adhesive tape...

Page 3: ...cted If the pipe has to be lengthened the refrigerant should be charged according to 20 g m But the charge of refrigerant must be conducted by profes sional air conditioner engineer Before adding addi...

Page 4: ...conditio ner according to the amount marked on the name plate Please do not let other cooling medium except speci ed one R410A or air enter into the cooling circulation system Otherwise there will be...

Page 5: ...de la unidad y que no ampli que el ruido y las vibraciones Seleccione un lugar en el que los residuos y el viento generado por la unidad no cause una molestia a los vecinos Coloque la unidad en un lug...

Page 6: ...gerante utilizando cinta protectora Entubaci n en otra direcci n Corte con una cuchilla la cubierta de entubaci n de acuerdo con la direcci n de entubaci n y doble los tubos de acuerdo con la posici n...

Page 7: ...so de que la elevaci n A sea superior a 5m el filtro de aceite debe instalarse cada 5 7 m Longitud m x Bm x 15m En caso de que la longitud del tubo B sea superior a 7m deber cargarse el refrigerante a...

Page 8: ...e contiene el producto de f brica 2 La cantidad de refrigerante adicional cargada durante la instalaci n y 1 2 La carga total de refrigerante en la etiqueta de refrigerante suministrada con el product...

Page 9: ...o dell unit dove le vibrazioni ed il rumore non siano aumentati Luogo dove l aria di scarico ed il rumore non provocano disturbo ai vicini di casa Luogo dove sia disponibile una distanza contrassegnat...

Page 10: ...la direzione della stessa e piegarla in base alla posizione del foro sulla parete Quando si piega prestare attenzione e non spaccare i tubi Connettere prima il cavo elettrico interno esterno quindi es...

Page 11: ...le tubature del refrigerante e dall unit interna usando una pompa a vuoto poi caricare il refrigerante A B A B A B AVVERTENZA Unit interna Unit da esterno Unit da esterno Trappola per l olio Unit inte...

Page 12: ...ante forni ta col prodotto L etichetta compilata deve essere attaccata accanto alla porta di caricamento del prodotto es all interno del coperchio con il valore di arresto A Questo prodotto contiene g...

Page 13: ...ez un emplacement capable de supporter l unit o les vibrations et le bruit n augmentent pas S lectionnez un emplacement o le vent et le bruit ne risquent pas de g ner les voisins Choisir un endroit da...

Page 14: ...eures ext rieures et le tuyau de vidange doivent tre x s au tuyau de r frig rant avec un ruban protecteur Tuyauterie dans une autre direction A l aide d une pince d coupez le couvercle pour la tuyaute...

Page 15: ...A B A B A B AVERTISSEMENT Unit int rieure Unit ext rieure Unit ext rieure Pi ge dl huile Unit int rieure Unit ext rieure Unit int rieure Hauteur max Amax 10m Si la hauteur A d passe les 5m installez...

Page 16: ...an te Merci de remplir l encre ind l bile 1 la charge de r frig rant standard de l appareil 2 la quantit suppl mentaire de r frig rant charg e sur place et 1 2 charge totale de r frig rant sur l tique...