background image

Indoor unit

1. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar
   qualified person. The type of connecting wire is H05/07RN-F or 245IEC57(YZW).
2. If the fuse on PC board is broken please change it with the type of T. 3.15A/250V.
3. The wiring method should be in line with the local wiring standard.
4. After installation, the power plug should be easily reached.

5

When connecting the cable before installing the indoor unit

Insert the cable from the back side of the unit, then pull it out on the front side.
Loosen the screws and insert the cable ends fully into terminal block, then tighten the screws.
Pull the cable slightly to make sure the cables have been properly inserted and tightened.
After the cable connection, never fail to fasten the connected cable with the wiring cover.
Note: When connecting the cable, confirm the terminal number of indoor and outdoor units carefully. If wiring
       is not correct, proper operation can not be carried out and will cause defect.

5. A breaker should be incorporated into fixed wiring. The breaker should be all-pole switch and the
    distance between its two contacts should be not less than 3mm.

HSU-09LE04

Indoor unit

Outdoor unit

4

HSU-12LE04

HSU-18LE04

Indoor unit

Outdoor unit

4

Indoor unit

Outdoor unit

4

1

2

N

L

HSU-22LE04

Indoor unit

Outdoor unit

4

L

N

POWER PLUG

{

1(L)

2(N)

{

power

connecting wiring:
-mod 07-12:    3G1.0mm
-mod 18:    3G1.5mm
-mod 22:    4G0.75mm

Power cable:
-mod 07-12:     3G1.0mm
-mod 18:    3G1.5mm
-mod 22:     3G2.5mm

-mod 24:    3G1.5mm

-mod 24:    3G1.5mm

FJT-12L

FJT-18L

FJT-24L

HSU-07LD03

Summary of Contents for HSU-07LD03

Page 1: ...r Drain hose Heating insulating material Piping hole cover Arrangement of piping directions Rear left Rear right Left Below Right The marks from to in the figure are the parts numbers The distance between the indoor unit and the floor should be more than 2m A G Attention must be paid to the rising up of drain hose more than 5cm more than 10cm more than 10cm A C No Accessory parts Remote controller...

Page 2: ...from televisions radios wireless apparatuses and fluorescent lamps can be left In the case of fixing the remote controller on a wall place where the indoor unit can receive signals when the fluorescent lamps in the room are lightened Place which is less affected by rain or direct sunlight and is sufficiently ventilated Place possible to bear the unit where vibration and noise are not increased Pla...

Page 3: ...rticle When the mounting plate is first fixed for the position of wall hole Fix to side bar and lintel a mounting bar Which is separately sold and then fasten the plate to the fixed mounting bar Make a hole of 60 mm in diameter slightly descending to outside the wall Install piping hole cover and seal it off with putty after installation Section of wall hole Piping hole pipe Outdoor side Thickness...

Page 4: ... aslant from the underside and then put it down perpendicularly Remove terminal cover at right bottom corner of indoor unit then take off wiring cover by removing its screws When connecting the cable after installing the indoor unit 1 Insert from outside the room cable into left side of the wall hole in which the pipe has already existed 2 Pull out the cable on the front side and connect the cable...

Page 5: ...ke sure the cables have been properly inserted and tightened After the cable connection never fail to fasten the connected cable with the wiring cover Note When connecting the cable confirm the terminal number of indoor and outdoor units carefully If wiring is not correct proper operation can not be carried out and will cause defect 5 A breaker should be incorporated into fixed wiring The breaker ...

Page 6: ...r operation can not be carried out and controller may be damaged If the drain elbow is used please attach it as figure Note Only for heat pump unit Drawing for the installation of indoor and outdoor units Insert the cable according to terminal number in the same manner as the indoor unit Fix the cable with a clamp Half union Flare nut Spanner Torque wrench 6 Outdoor unit Forced fastening without c...

Page 7: ...ional amount 5m 7m No need 40g 10m 100g for 7k 9k 12k 18k Push the air out of the indoor unit and piping as followes 1 Remove the valve cap on 2 way valve in outdoor unit 2 Loosen by 1 2 turn the flare nut of gas pipe which is is conneted to 3 way valve 3 Loosen 2 way valve by 90o using hexagon wrench and after approx 10 sec tighten it up Gas comes out through flare nut on wide pipe If no gas is d...

Page 8: ...onfirm that drainage is carried out surely to outdoor In case that the attached drain hose is in a room please apply heat insulation to it without fail Please kindly explain to our customers how to operate through the instruction manual Gas leak from pipe connecting Heat insulation of pipe connecting Are the connecting wirings of indoor and outdoor firmly inserted to the terminal block Is the conn...