Installation introduction 

Installation  caution

When making the 

connections, you should respect  the standards and   

local directives.

- Before making the connection,

 rinse the water inlet pipes

, in order not to 

   introduce metal or other particles into the tank.

- Select copper pipes for  pipeline connection.

- The inlet water pressure is be

tween 0.1~0.5MPa. If  lower than 0.1 MPa, a 

    booster pump shall be added at the water inlet; if higher than 0.5 MPa, a 
    pressure relief valve shall be added at the water inlet.

-  The inlet water temperature is suggested between 10-30°C.

-  Outdoor water pipeline and valves should be proper insulated.

- In accordance with safety rules, a safety valve(8bar,G1/2F) must be 
  installed on the tank.For France, we recommend hydraulic safet

tted 

  with a membrane with the NF marking.
  Integrate the safety valve in the cold water circuit.Install the safety valve close 
  to the tank in a place which is easy to access.
  No isolating devices should be located between the safety valve or unit and the 
  tank.
  The rated pressure of the safety valve shall not exceed 0.8MPa.
  
-

 

Never block the outlet of the safety valve or its drain line for any reason.

- The diameter of the safe

ty unit and its connection must be atleast equal to the 

   diameter of the domestic 

cold water inlet.

- If the mains pressure exceeds 80% of safety valve, a pressure reducer must be 
   installed upstream of the appliance.

If the air inlet and outlet of the product are not installed with air ducts, 

the air inlet and outlet of the product shall be protected to prevent water 

15

E

n

g

lis

h

-  NOTE: Don’t install and use the product outdoors.

Summary of Contents for HP80M5

Page 1: ...Operation and Installation Manual Model HP80M5 HP110M5 Please read this manual carefully prior to your use of this water heater The appearance of the water heater given in this manual is for reference only English ELECTRICITE ...

Page 2: ...best installation and utilization of the product Product safety statement 1 This appliance can be used by persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved 2 Children shall be closely supervised to make sure they stay aw...

Page 3: ...th power supply with a ground line ground connection It is recommended that the water heater shall be installed inside The water heater shall not be installed at places where water drainage is unavailable or impossible While bathing children must be under guidance of an adult person This water storage tank must be equipped with a safety valve Its installation position shall not be changed To guara...

Page 4: ...ing a contact separation in all poles that provide full disconnection under overvoltage category III conditions must be wiring in accordance with the wiring rules If the power cord is damaged it shall be replaced by avoid hazards Install the water heater in strict accordance with the installation instruction Maintenance shall be carried out according to the page 27 Safety instructions to be follow...

Page 5: ...xceed 30 mA Safety instructions to be followed at any time The water drain pipe shall be in connection with the atmosphere it shall not be blocked the water drain pipe connected to a safety valve shall be installed in a frostless environment with an continuous downwards inclination 5 English Inaccordancewith safetyrules asafety valve 8bar G1 2F must be installed on the tank For France we recommend...

Page 6: ...ide of the package case The heat pump water heater after being laid down for a certain time shall be kept at upright position for more than 4 hours before starting up The machine shall be kept in the upright position at any time for the best performance into the compressor As the pressure of the refrigerant increases so does its temperature The heated refrigerant runs through a condenser coil with...

Page 7: ...ime 7 5h07 6h38 Heating up time 14 4h35 5h56 Default temperature setting 54 54 Temperature setting range with heater 35 75 35 75 Maximum lengthofairduct 160mm Max working pressure ofrefrigerant 0 8 2 8MPa 0 8 2 8MPa Refrigerant type weight R134a 0 45kg R134a 0 45kg Sound power level 50dB A 50dB A Ambient temperature foruse ofproduct 7 45 7 45 Operating temperature ofheat pump 7 45 7 45 Waterinlet ...

Page 8: ...fety val ve Drainage pipe for condensate water Support plate Quantity 1 1 1 1 Inlet for cold water drain outlet Hot water outlet Heat pump structure 8 Condensate outlet Air outlet Air inlet Instruction manual 1 HW SE T ACT START STOP 1 2 HP HC TI MER MOD E HP SE T ACT T OP SE T BOOS T ...

Page 9: ...r 2 Electric cover 3 Cover for display 4 Display panel 5 Front cover 6 Control box 7 Compressor 8 Air grille 9 ront 10 F an 11 Four way valve 12 Top cover 13 14 15 Description 16 15 14 8 7 13 11 10 18 9 Electronic expansion valve Evaporator 16 Motor 17 Back cover 18 Support plate English ...

Page 10: ...Installation introduction Installation precaution Keep an adequate distance between the working heat pump and the resting room and the condensate water can be drained freely functions running from 2 10 ...

Page 11: ...English Installation introduction Installation dimensions M odel HP80M5 HP110M5 A B 140 140 492 492 C 1170 D 538 538 1320 E Unit mm 11 A B D E C F 159 159 362 362 F ...

Page 12: ... angle refer t o the following diagrams 300mm 830mm 90 91 159mm Note these two expansion bolts can support 200kg weight at least After the installation is completed it is necessary to use a level ruler to check whether the support is maintained in a horizontal state ...

Page 13: ...English Installation introduction Air connection 160mm duct the fan impaired The sum of the maximum length of the air duct is 5m 13 click ...

Page 14: ... room without ducts Laundry room with one duct Habitable room or outside air with two ducts too low connection to the outside air may lead to overconsumption of electricity 14 Installation introduction Advised positions ...

Page 15: ...n the tank For France we recommend hydraulic safet tted with a membrane with the NF marking Integrate the safety valve in the cold water circuit Install the safety valve close to the tank in a place which is easy to access No isolating devices should be located between the safety valve or unit and the tank The rated pressure of the safety valve shall not exceed 0 8MPa Never block the outlet of the...

Page 16: ... water outlet Cold water inlet Water outlet Stop valve Pressure relief valve Check valve 230V 50Hz Con nected to water inlet of the water tank Check valve Stop valve Safety valve Sewage drainage outlet Thermostatic valve W ater outlet of safe ty valve Check valve Pressure relief valve Combination valve Outlet of condensate water Hot water outlet Cold water inlet Water outlet 230V 50Hz 2CM 16 Drain...

Page 17: ...less than 1 8 m and it shall be ensured that water would n ot be splashed on these places The socket shall be installed out of children s reach The phase line zero line and ground line inside a power socket used in your home shall be wired correctly without any wrong positioning or false connection and internal short circuit shall be avoided Wrong wiring may s WARNING rofessionals may carry out el...

Page 18: ...Installation introduction 18 Power cable 3 1 5mm 2 2 0 75mm2 Black wire 16A Auto 1 0 123kwh 1 0 ...

Page 19: ...fter pressure is Installation introduction R S C K3 CT1 Blue MAIN BOARD FAN K4 K5 L N CN9 CN19 CN16 N Leakage protection coil GND Compressor capacitor White Compressor Blue Blue White Black Brown Blue Four way valve White Discharge temperature sensor Defrost temperature sensor Ambient temperature sensor Suction temperature sensor Water tank temperature sensor Power cord CN1 EXV CN5 CN2 CN11 Termin...

Page 20: ...e and starts after approximately 3 minutes which is considered to be normal The defrosting mode is automatically activated if the outdoor temperature is too low and after the compressor already runs continuously for a certain period The working load of the compressor will be heavy if temperature is high in summer In order to meet hot water requirements of users and to lengthen service life of the ...

Page 21: ...tivated at the same time Working mode selection Auto mode for guaranteed comfort the auxiliary power compressor maximum continuous working time can be adjust in the installer settings Description of the pictograms hot water 4th automatically Holiday mode is not working properly Electric heating mode ...

Page 22: ... the signal HC lights up legionella Under certain conditions ECO mode may result in shortages of hot water mainly due to air temperatures outside the operating range When the PV function is turnedon the setting temperature will be automatically adjusted to 65 is received theheatpump andelectricheating willbeturnedon at the same time When receiving the SG signal the setting temperature will be auto...

Page 23: ...mpanies 03 PV signal 04 SG signal NO 01 ON 8h 5 10h NO NC 01 02 03 04 ON OF d1 d7 Set the day of the week Factory setting Adjustment range Avoid Legionella This parameter is used to activate the legionella protection mode Once every 7 days all domestic hot water is heated to 65 C Set the day of the week d1 to d7 for Monday to Sunday and remember the day of the week NO corresponds to Normally Open ...

Page 24: ... every six months to check if it is running correctly Otherwise check for blocking and replace the safety valve if necessary Checking of the condensates discharge pipe Checking of the Magnesium rod water in the heat pump plastic base time 24 Drain the water tank to empty via the sewage outlet Please stay away from the sewage outlet if there is hot water inside the water tank to avoid injury ...

Page 25: ...f the air intake temperature sensor If short circuit or circuit break occurs to the sensor ED Communication fault Communication of main control panel and display panel is abnormal E7 Pressure switch protection Action of the pressure switch at the exhaust outlet E8 Ambient temperature protection Ambient or outdoor temperature 7 or 45 E9 F2 F3 F5 F6 The symbol on the product or on its packaging indi...

Page 26: ...power level indoors Mixed water at 40 C Load profiles of water heaters Type Qingdao Economic Technology Development Zone Haier Water Heater Co Ltd Haier Industry Park Economic Technology Development Zone 266101 Qingdao PEOPLE S REPUBLIC OF CHINA Heat pump water heater Hot water Power supply The water heating energy efficiency wh Water heating energy efficiency class Annual energy consumption AEC 1...

Page 27: ......

Page 28: ...0040510083 20210218 V ...

Reviews: