Rotate the safety valve handle
once a month. The valve
works well if there is water
for blocking and replace the
●
safety valve if necessary.
Chemical name of the gas: R134a/ 0,45Kg
●
Fluorinated
greenhouse
gases
are
contained
in
hermetically sealed equipment.
Global Warming Potential(GWP) : 1430
Water
heaters
shall
be
equipped with a dedicated
power
line
and
residual
current circuit breakers. The
action
current
shall
not
exceed 30 mA;
Safety instructions (to be followed at any time)
The water drain pipe shall be in connection with the
atmosphere, it shall not be blocked; the water drain pipe
connected to a safety valve shall be installed in a frostless
environment with an continuous downwards inclination.
5
●
E
n
g
lis
h
In accordance with safety rules, a safety valve(8bar,G1/2F)
must be installed on the tank. For France, we recommend
marking. The rated pressure of the safety valve shall not
exceed 0.8MPa.
If needed, please refer to the wiring diagram on page 23.
The method of connection about the appliance to the
electrical supply refer to page 21.