Checking and maintenance
Checking of the Safety valve
- Installation and maintenance of the appliance must be done by a qualified
professional .
- Before working on the appliance,Shut down the machine and cut off the power
supply .
- Do not touch with wet hands.
- Maintenance operations are important to guarantee optimum performance
and extend the life of the equipment.
Checking of the hydraulic circuit
Cleaning of the fan
- Check the watertightness of the water connections.
- Because the evaporator fins is very sharp.Risk of injury on your finger.
- Do not damage the fins. Avoid affecting the performance.
- Check the cleanliness of the fan one time per year.
Checking of the evaporator
- Clean the evaporator at regular intervals using a soft-haired brush.
- If they are bent.Carefully realign the evaporator using a suitable comb.
- Operate the safety valve at least once a month to check if it is running
correctly. Otherwise check for blocking and replace the safety valve if necessary.
Checking of the condensates discharge pipe
Checking of the Magnesium rod
- Check the pipe cleanliness .
- An obstruction by dust may cause poor condensates flow or even a risk accumulation of
water in the heat pump plastic base.
- The magnesium anode should be replaced in time, avoid tank corrosion.
- Checking magnesium anode once every 2 years .In poor water areas need to shorten the
time.
28
Drain the water tank to empty
-Cut off power supply and shut down water inlet valve, then drain the water tank to empty
via the sewage outlet. Please stay away from the sewage outlet if there is hot water inside
the water tank to avoid injury.