Operating functions
Installer settings
Parameters
,
Description
- To open the installer settings, press switch off the system, then press and
at the same time for 10 seconds.
- When menu is open, press or to change the value of the settings.
- Press to confirm the settings.
- Press to close the menu.
Off-peak signal type
Off-peak
logic
type
When you use off-peak time clock control, first determine
the type of signals,Only allow professional installers to operate.
- In two ways using heat pump,should set in the installer
settings
-01 manually set off-peak time;
-02 switch signals by power companies.
NO
01
ON
NO , NC
01 , 02
ON , OF
,
,
8h
5-10h
C
ompressor maximum continuous working time
- If the
maximum continuous working time
of the compressor
more than Set Time, start auxiliary
power
.
-
Factory
setting
Adjustment
range
Avoid Legionella
- This parameter is used to activate the legionella protection
mode.
- Once every 7 days, all domestic hot water is heated to 65
℃
.
- NO corresponds to Normally Open Signal.
- NC corresponds to Normally Close Signal.
27
Auxiliary Heating in off-peak time
- ON corresponds to turned on uxiliary Heating.
- OF
corresponds to turned o
ff
uxiliary Heating.
,
ON
ON , OF
English