507332-02G / 31-5000663
Page 25 of 35
Issue 2209
Figure 24.
103217-03 Integrated Control
(Automatic Hot Surface Ignition System)
RED LED RECALL BUTTON
BLOWER OFF DELAY
Figure 25.
107163-01 Integrated Control
Heating Blower Off
Delay Selector Switch
Diagnostic LED
Push Button
Error Recall
PARK
HUM2
4
FS
24VCOM
COOL
HE
AT
FA
N
W
C
R
G Y
1/4” Quick Connect Terminal Designations
120V HUM
Power for Humidifier (120VAC)
LINE
Incoming Power Line (120VAC)
XFMR
Transformer Primary (120VAC)
CIRC
Indoor Blower Motor (120VAC)
EAC
Electronic Air Cleaner (120VAC)
HUM24
Power For Humidifier (24VAC)
NEUTRALS (5)
Neutral
3/16” Quick Connect Terminal Designations
COOL
Cool Speed From Indoor Blower Motor
(24VAC)
HEAT
Heat Speed From Indoor Blower Motor
(24VAC)
FAN
Continuous Fan Speed From Indoor
Blower Motor (24VAC)
PARK (3)
Terminals For Unused Motor Speed
Taps
FS
Flame Sensor Electrode (120VAC)
24V COM
Common (24VAC)
Table 13. Terminal Designations
(Applicable to 103217-03 and 107163-01 Controls)