background image

TECHNICAL GUIDE

96% AFUE TWO STAGE STANDARD ECM
RESIDENTIAL GAS FURNACES
MULTI-POSITION 
MODELS: TM9Y

NATURAL GAS

40 - 120 MBH INPUT

Due to continuous product improvement, specifications are 
subject to change without notice.
Visit us on the web at www.york.com

Additional rating information can be found at 

www.ahridirectory.org

WARRANTY SUMMARY

A 20-year limited warranty on heat exchangers in residen-

tial applications.

A 10-year warranty on the heat exchanger in commercial

applications.
Standard 5-year limited Parts warranty.

Extended lifetime heat exchanger and 10-year limited
parts warranty when product is registered online within
90 days of purchase for replacement or closing for new
home construction.

See Limited Warranty certificate in Users Information Manual for details.

5129599-YTG-B-1115

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

DESCRIPTION

These compact units employ induced combustion, reliable hot
surface ignition and high heat transfer aluminized steel tubular
primary heat exchangers. The units are factory shipped for
installation in upflow or horizontal applications and may be con-
verted for downflow applications.

These furnaces are designed for residential installation in a
basement, closet, alcove, attic, recreation room or garage and
are also ideal for commercial applications. All units are factory
assembled, wired and tested to assure safe dependable and
economical installation and operation.

These units are Category IV listed and may be vented either
through side wall or roof applications using approved plastic
combustion air and vent piping.

FEATURES

Two stage heating operation includes two stage gas valve,
two stage inducer operation and constant torque standard
ECM blower operation. Adjustable delay timer allows two
stage operation with a single stage thermostat.

Easily applied in upflow, horizontal left or right, or downflow
installation with minimal conversion necessary.

Compact, easy to install, ideal height 33" tall cabinet.

Standard ECM constant torque drive for cooling SEER
enhancement, improved comfort with optional airflow delay
profiles, and continuous fan options for IAQ performance.

Easy access to controls to connect power/control wiring.

Built-in, high level self diagnostics with fault code display.

Low unit current draw requirement for easy replacement
application.

All models are convertible to use propane (LP) gas.

Electronic Hot Surface Ignition saves fuel use with
increased dependability and reliability.

100% shut off main gas valve for extra safety.

24V, 40 VA control transformer and integrated furnace con-
trol supplied for add-on cooling.

Hi-tech tubular aluminized steel primary heat exchanger
with stainless steel tube/aluminum fin secondary heat
exchanger for outstanding efficiency.

Solid removable bottom panel allows easy conversion.

Airflow leakage less than 1% of nominal airflow for duct

blaster conditions.

No knockouts to deal with, making installation easier.

Movable duct connector flanges for application flexibility.

Quiet inducer operation, burner, and blower operation.

Inducer rotates for easy conversion of venting options.

Fully supported blower assembly for easy access and
removal of blower.

External air filters used for maximum flexibility in meeting
customers IAQ needs.

Insulated blower compartment for thermal and acoustic per-
formance.

1/4 turn knobs provided for easy independent door removal.

Internal condensate trap design (patent pending) provides
condensate management options and is self priming to pre-
vent nuisance problems.

Protection included from air intake, exhaust vent or conden-
sate blockage.

Venting applications maybe installed as either 2 pipe sealed
combustion or single pipe vent using indoor combustion air.

Summary of Contents for TM9Y120D20MP11

Page 1: ...timer allows two stage operation with a single stage thermostat Easily applied in upflow horizontal left or right or downflow installation with minimal conversion necessary Compact easy to install ideal height 33 tall cabinet Standard ECM constant torque drive for cooling SEER enhancement improved comfort with optional airflow delay profiles and continuous fan options for IAQ performance Easy acce...

Page 2: ...13 3 8 11 3 4 113 TM9Y060B12MP11 1200 B 17 1 2 16 3 8 13 1 4 119 TM9Y080B12MP11 1200 B 17 1 2 16 3 8 14 3 4 123 TM9Y080C16MP11 1600 C 21 19 7 8 16 1 2 130 TM9Y100C16MP11 1600 C 21 19 7 8 18 1 4 136 TM9Y100C20MP11 2000 C 21 19 7 8 18 1 4 143 TM9Y120D20MP11 2000 D 24 1 2 23 3 8 21 3 4 154 Ratings Physical Electrical Data Model Input High Low Output High Low Total Unit AFUE High Fire Air Temp Rise Lo...

Page 3: ...ter racks 1BR06xx are pre painted steel filter racks to match the appearance of the furnace cabinet S1 1BR0514 or 1BR0614 For 14 1 2 cabinets S1 1BR0517 or 1BR0617 For 17 1 2 cabinets S1 1BR0521 or 1BR0621 For 21 cabinets S1 1BR0524 or 1BR0624 For 24 1 2 cabinets Combustible Floor Base Kit For installation of these fur naces in downflow applications directly onto combustible floor ing material The...

Page 4: ...7 1128 1097 1069 1013 Medium 1098 1084 1059 1027 998 967 939 910 879 822 Medium Low 1012 993 953 930 894 851 828 773 752 692 Low 865 810 763 730 689 628 594 520 496 448 80C High 1713 1682 1643 1600 1558 1519 1480 1436 1385 1333 Medium High 1554 1519 1485 1439 1404 1368 1327 1280 1176 1130 Medium 1380 1351 1302 1263 1224 1171 1128 1085 1030 943 Medium Low 1177 1142 1083 1050 988 922 890 819 798 687...