Air Delivery Clearances
Standard clearances for cassette air handlers require
5 feet of clearance in each direction. There should be
8 feet of clearance from the face of the cassette grille
to the floor. Inadequate clearances can cause system
freezing and temperature control problems.
Service and Maintenance Clearances
Make sure there are adequate clearances for future
maintenance and service. Allow enough room to access
the condensate pump assembly and the electrical
control box.
MINIMUM CLEARANCES
(Appearance may vary)
This picture is for reference only. Your product may look different.
Installation Instructions
Step 1 - Preparation
A. Procedure for selecting the location:
• Place above the ceiling where you have enough
space to position the unit.
• Place where the drainage pipe can be properly
positioned.
• Place where the inlet and outlet air of the indoor unit
will not be blocked.
• Do not install the unit in a place with heavy oil or
moisture (e.g. - kitchens and workshops)
• Do not install in a location with destructive gas (such
as sulfuric acid gas) or pungent gas (thinner and
gasoline) are used or stored.
• Choose a place solid enough to bear the weight and
vibration of the unit and where the operation noise
will not be amplified.
• Install where there are no expensive items like a
television or piano below the indoor unit.
• Leave enough space for maintenance.
• Install at least 3 ft. away from televisions and radios
to avoid interference.
NOTES:
• R-410A refrigerant is a safe, nontoxic and
nonflammable refrigerant. However, if there is a
concern about a dangerous level of refrigerant
concentration in the case of refrigerant leakage, add
extra ventilation.
5 ft.
5 ft.
1 ft.
8 ft. Over