Page 4
31-5000752 Rev. 0
UNIT SOUND RATINGS
Model
Sound Power
1
Estimated Sound Pressure (dBA)
2
Approximate Distance
3
3.3 Feet
(1 Meter)
6.6 Feet
(2 Meters)
9.8 Feet
(3 Meters)
NS17H18SA4
74
66
60
56
NS17H24SA4
74
66
60
56
NS17H30SA4
74
66
60
56
NS17H36SA4
75
67
61
57
NS17H42SA4
78
70
64
60
NS17H48SA4
79
71
65
61
NS17H60SA4
79
71
65
61
1 Rated in accordance with AHRI standard 270 (2015)
2 Rated in accordance with AHRI standard 275 (2010)
3
Based only on distance factor; other factors may change this value such as:
- Unit location (reflective surfaces adjacent to the unit)
- Barrier shielding sources
- Sound path/elevation
- Outside noise sources
REFRIGERATION DATA
Model
Refrig. Charge
(Oz.)*
TXV
Refrigerant Line Size
Outdoor Unit Connection
Indoor Unit Connection
Suction
Liquid
Suction
Liquid
Suction
Liquid
NS17H18SA4
98
H4TXV01
3/4
3/8
3/4
3/8
3/4
3/8
NS17H24SA4
96
H4TXV01
3/4
3/8
3/4
3/8
3/4
3/8
NS17H30SA4
117
H4TXV01
3/4
3/8
3/4
3/8
3/4
3/8
NS17H36SA4
137
H4TXV02
7/8
3/8
7/8
3/8
7/8
3/8
NS17H42SA4
162
H4TXV02
7/8
3/8
7/8
3/8
7/8
3/8
NS17H48SA4
146
H4TXV02
7/8
3/8
7/8
3/8
7/8
3/8
NS17H60SA4
164
H4TXV03
1-1/8
3/8
1-1/8
3/8
7/8**
3/8
* Factory charged for 15 feet of line set; adjust per installation instructions.
** Field supplied adapter required
COOLING PERFORMANCE WITH AIR HANDLERS AND FURNACES
Outdoor Model
Indoor Model
Cooling
Heating
Evap. Coil or Air
Handler
3
SEER
SEER2
EER
EER2
AHRI
Rated
Capacity
1
Sensible
Capacity
HSPF
HSPF2
47°
17°
Btuh
COP
Btuh
COP
NS17H18SA4
NAM18P1TA4
15.5
15.2
13.0
13.0
18,000
14,400
9.2
8.0
17,900
3.80
11,200
2.54
NS17H24SA4
NAM24P1TA4
15.5
14.7
13.0
12.4
23,200
17,800
9.6
8.0
22,200
3.72
14,000
2.54
NS17H30SA4
NAM30P1TA4
15.0
14.4
12.2
12.0
28,400
22,400
9.2
8.0
27,800
3.56
18,000
2.52
NS17H36SA4
NAM36P1TA4
15.5
14.7
12.5
12.4
35,600
27,000
9.6
8.0
34,000
3.62
22,400
2.56
NS17H42SA4
NAM42P1TA4
15.0
14.4
12.2
12.0
40,500
30,800
9.2
7.8
39,000
3.40
25,000
2.46
NS17H48SA4
NAM48P1TA4
15.4
14.7
12.5
12.4
47,000
35,400
9.8
8.2
46,500
3.64
30,400
2.64
NS17H60SA4
NAM60P1TA4
15.1
14.3
12.5
11.7
56,500
41,500
9.6
8.0
54,000
3.50
35,000
2.56
Note:
1 Certified in accordance with Unitary Air Conditioner Certification Program, which is based on AHRI Standard 210/240
3 Blower time delay relay is standard on all GE Appliances furnace and AH products.
Summary of Contents for GE APPLIANCES NS17HS
Page 7: ...Page 7 31 5000752 Rev 0 Figure 1 Typical Parts Arranegment Figure 2 Typical Parts Arranegment...
Page 29: ...Page 29 31 5000752 Rev 0 Figure 11 Typical Factory Wiring 018 through 036 models...
Page 30: ...Page 30 31 5000752 Rev 0 Figure 12 Typical Factory Wiring 042 through 060 models...
Page 31: ...Page 31 31 5000752 Rev 0 Figure 13 Wiring Diagram 018 036 Models...
Page 32: ...Page 32 31 5000752 Rev 0 Figure 14 Wiring Diagram 042 060 Models...
Page 43: ...Page 43 31 5000752 Rev 0 Notes...