![Haier EA-1770 EG Service Manual Download Page 25](http://html.mh-extra.com/html/haier/ea-1770-eg/ea-1770-eg_service-manual_137214025.webp)
Circuit Diagram and Circuit Explanation
1. After the oven start working, a 230V AC voltage is added between the two ends of the
high-voltage transformer.
2. The 230V voltage will make 2000V induction voltage between the two ends of the
high-voltage coil, and 3.5V low-voltage between the two ends of the heater winding.
3. The 2000V voltage will be doubled by the high-voltage capacitor, then be rectified by the
high-voltage diode, finally become a 4000V negative high-voltage to ground at the FA end
of the magnetron.
4. One end of the heater coil is connected to the negative high-voltage, the other end to the F
end of the magnetron. Therefore the working condition of the magnetron is made up:
low-voltage and high electric potential.
Exploded View
Magnetron
AK
Rectifier
HVT
HVD
HVC
230 50Hz
10.Exploded View(EA
-
1770EG)