year.
down hinge with cross screwdriver.
Maintenance Service and Trouble Shooting
②
Pull up the door towards you to
take off it.
Attention:
After installation of the oven door, please check if the first/second lockout switch and
monitoring switch work well.
After oven door is installed, check the leakage with leakage detector.
Attention:
In installation, please install gasket on the up/down
hinge.
In installing the door, the
position of the door can be calibrated by adjusting the up/down hinge. At the same time
please note that 0.4mm gap is required between the inside surface of the door and the front
board of the cavity. (You can add 3-4 pieces of paper between the door and the front board.
Too big gap may cause excessive leakage of microwave; too small gap may cause
overheating of the door and the front board.)
10
E. Dismantling of the high-voltage transformer
①
Discharge the electricity of the high-voltage capacitor.
②
Dismantle the connecting
high-voltage wires of the magnetron, the high-voltage transformer and the high-voltage
capacitor.
③
Loosen the four screws connecting the high-voltage transformer to the bottom plate with
cross screwdriver.
F. Dismantling of the fan motor
①
Discharge the electricity of the high-voltage capacitor.
②②
Dismantle the connecting wires between the fan motor, filter and high-voltage capacitor.
③
Loosen the screw connecting the high-voltage diode to the bottom plate with cross
screwdriver.
④
Loosen the four screws connecting the flare, fan motor and rear board.
⑤
Lift the flare up to take out the flare group. Pull off the fin and take out the fan motor
backward.
G. Dismantling of the high-voltage capacitor, diode and AK rectifier
①
Take off the flare group
②
Loosen the screw connecting the flare to the high-voltage
capacitor.
③
Take off the high-voltage group
④
Pull off the plug of the high-voltage diode and the AK
rectifier with nipper pliers.
- 13 -