Stepper Motor and Louver
Fan Motor
Emergency Button
The Stepper Motor moves the louver up and down. The
motor is connected to the Indoor Control Board at Plug
CN-11. Louver left and right funcution is not available for
Tempo series
The Indoor Fan Motor is a variable speed DC motor. The
motor will vary speed with the speed of the compressor.
The speed can also be changed at the remote control
or automatically adjusted using the AUTO fan mode. When
in AUTO fan mode, the speed of the fan is calculated using
the indoor set temperature and the indoor room ambient
temperature. (Outdoor air temperature in heat mode.)
The Fan Motor is connected to the indoor control board via
PLUG CN-9.
If the remote control is non-functional, the Emergency
Button can be accessed by swinging open the front of the wall
unit. The button is located on the right side.
Pushing this button will activate AUTO MODE operation.
AUTO MODE activated with this button will maintain 75°F.
The system will stay in this mode until commands are
received by the indoor unit communication circuit via the
remote control.There is a discrepancy here. Some literature
indicates auto mode, others say cooling mode.
Summary of Contents for AW09TE1VHA
Page 2: ... This page intentionally left blank ...
Page 6: ...INTRODUCTION PAGE 6 ...
Page 18: ...REMOTE CONTROL FUNCTIONS PAGE 18 ...
Page 32: ...SEQUENCE OF OPERATION PAGE 32 ...
Page 42: ...INSTALLATION PAGE 42 ENGLISH This page intentionally left blank ...
Page 57: ...REFERENCE INFORMATION PAGE 57 ENGLISH Outdoor Board Schematic 9 12K ...
Page 58: ...REFERENCE INFORMATION PAGE 58 Outdoor Board Schematic Outdoor Board Schematic ENGLISH ...
Page 62: ...REFERENCE INFORMATION PAGE 62 ENGLISH Indoor Board Schematic 09 12K ...