DIP Switch Settings
Description
SW5-1 SW5-2 SW5-3 SW5-4 SW5-5 SW5-6 SW5-7 SW5-8
Cooling Only
ON
----
----
----
----
----
----
----
Heat Pump OFF*
----
----
----
----
----
----
----
Set On For Colder Climates
----
ON
----
----
----
----
----
----
Set Off For Normal Operations
----
OFF*
----
----
----
----
----
----
Max Running Current Is 15Amps
----
----
ON
----
----
----
----
----
Normal Conditions
----
----
OFF*
----
----
----
----
----
4U36HS1ERE & 4U36MS2VHB
----
----
----
ON
----
----
----
----
3U24GS1ERE & 3U24MS2VHB
----
----
----
OFF
----
----
----
----
3U24GS1ERE & 3U24MS2VHB
----
----
----
----
ON
----
----
----
4U36HS1ERE & 4U36MS2VHB
----
----
----
----
OFF
----
----
----
4U36HS1ERE & 4U36MS2VHB
----
----
----
----
----
ON
----
----
3U24GS1ERE & 3U24MS2VHB
----
----
----
----
----
OFF
----
----
Temperature Correction Valid
----
----
----
----
----
----
ON
----
Temperature Correction Null
----
----
----
----
----
----
OFF*
----
Quiet Operation Valid
----
----
----
----
----
----
----
ON
Quiet Operation Invalid
----
----
----
----
----
----
----
OFF*
Note:
1. Power input restrict
selection: OFF-invalid; ON-valid(≤3500W)
2. Quiet operation: If OFF, the outdoor unit will calculate and obtain the average ambient temperature of the unit within the
last 24 hours, Tao_average_24. Then compare the current ambient temperature with the ambient temperature average
Tao_average_24, and combine it with the previous ambient temperature trend to determine whether it can enter Quiet
operation (low compressor speed and low O.D. fan speed).
SW5 DIP Switch Settings (3U24MS2VHB, 4U36MS2VHB)
*Factory Default Setting
SM2 DIP Switch Settings (2U18MS2VHB)
Description
SM2-1
SM2-2
Enhanced Defrost (Cold Climates) OFF
OFF
Defrost frequency is reduced by 10Hz compared with OFF/OFF state
ON
OFF
Defrost frequency is increased by 10Hz compared to OFF/OFF state
OFF
ON
Demand Defrost (Default Setting)
ON
ON
Summary of Contents for AW07EH2VHA
Page 2: ...Aug 2020 Manual release Revision History ...
Page 12: ... This page intentionally left blank ...
Page 30: ...OUTDOOR TECHNICAL OVERVIEW B 18 ENGLISH Wiring Diagrams 2U18MS2VHB ...
Page 31: ...OUTDOOR TECHNICAL OVERVIEW B 19 ENGLISH Wiring Diagrams 3U24MS2VHB ...
Page 32: ...OUTDOOR TECHNICAL OVERVIEW B 20 ENGLISH Wiring Diagrams 4U36MS2VHB ...
Page 36: ... This page intentionally left blank ...
Page 45: ...WALL MOUNT TECHNICAL OVERVIEW C 9 ENGLISH Topic Title Wiring Diagrams ...
Page 68: ... This page intentionally left blank ...
Page 78: ... This page intentionally left blank ...
Page 100: ...MEDIUM STATIC DUCTED PRO SERIES TECHNICAL OVERVIEW H8 ENGLISH Topic Title Wiring Diagram ...
Page 114: ... This page intentionally left blank ...
Page 122: ...TROUBLESHOOTING REFERENCES J 10 ENGLISH Refrigeration Diagrams 3U24MS2VHB Refrigerant Diagram ...