Commercial Air Conditioner
Model: AU182AFERA
AD182AMERA, AS182AVERA
Function
cooling
heating
Capacity
kW
5.1
(
1.8---6.0
)
6.0
(
2.0---7.1
)
Sensible heat ratio
0.75
W
1580
(
550---2650
)
1650
(
600---2650
)
W
2650
2650
EER or COP
W/W
3.23
3.64
Dehumidifying capacity
10
‐
³×m³/h
Power cable
Power source
N, V, Hz
A / A
7.5
(
3.0---12.0
)
/12.0 7.8
(
3.2---12.0
)
/12.0
Start Current
A
3
3
Unit model (color)
Type × Number
Speed(H-M-L)
r/min
Fan motor output power
kW
Air-flow(H-M-L)
m³/h
Type / Diameter
mm
Total Area
m²
Temp. scope
℃
External
(
L×W×H
)
mm×mm×mm
Package
(
L×W×H
)
mm×mm×mm
Drainage pipe (material , I.D./O.D.)
mm
Control type (Remote /wired)
Fresh air hole dimension
mm
kW
dB(A)
kg / kg
Type / Charge
g
Recharge quantity
g/m
Liquid
mm
Gas
mm
Connecting Method
m
m
item Model
AD182AMERA
Total power input
Max. power input
Heat exchanger
inner grooved pipe/
φ
9.52
0.59
/
4.0×3
1, 220--230, 50
Running /Max.Running current
Dimension
1190*450*220
1281*526*305
Indoor unit
AD182AMERA(WHITE)
Fan
cross flow*1
1150/1050/860/680R/MIN
0.05
850/770/680/600(30PA)
PVC 16/12
wired
/
2-7
Electricity Heater
0
Noise level (H-M-L)
50/48/45
Weight (Net / Shipping)
24/27
PIPING
Refrigerant
R410A/1850
35
Pipe
6.35
12.7
flared
Between I.D &O.D
MAX.Drop
15
MAX.Piping length
40
-8-