emergency operation as Auto mode.
17.2 In OFF state, press emergency switch for over 5 seconds and below 10 seconds
contineously, the unit will begin trial running in cooling mode (30 minutes later quit the trial
running).
17.3 In OFF state, press emergency switch for over 10 seconds and below 15 seconds
contineously, the unit will show the previous failure.
17.4 In OFF state, press emergency switch, there will be Auto operation on the panel.
17.5 In OFF state, press emergency switch for less than 15 seconds, the unit will not receive
the remote signal. If over 15 seconds, the unit will in OFF state, and can receive the remote
signal.
17.6 In running, press emergency switch, the unit will shut off.
17.7 If abnormal condition occurs, press emergency switch, the unit will shut off.
17.8 When failure code displays, press emergency switch, the failure code will not display.
17.9 In running, when the unit is normal or abnormal, or failure code occurs, press emergency
switch contineously, at this case, the unit can receive the remote signal.
17.10 Failure code display
Press emergency switch for up to 10 seconds, and sounds 3 times, if releasing the switch, the
unit will display failure record. If pressing the switch time is up to 15 seconds, no display on the
panel, and the failure record is cancelled.
Remark: The latest record will not be cancelled when being powered off, and the data will be
saved in EEPROM. The previous alarm will display on the indication board.
10 seconds later, the failure record will be cancelled.
-71-