.9773:1506 -5: .9825;5983:
1.Description of products & features
1.1. Products code explanation
3 U 19 F S 1 E R A
Climate type: T1 (see table 1)
Frequency type: DC inverter
Product type: A stands for heat pump type, refrigerant is R22
B stands for heat pump type, refrigerant is R407C
E stands for heat pump type, refrigerant is R410A
N stands for cool only type, refrigerant is R407C
Design edition
Product series: S stands for EASY STOCK
Product appearance
Cooling / Heating capacity,19=19000BTU/h
Product type : “B” stands for cassette type, “C” stands for
convertible type, “D” stands for duct, “S” stands for wall
mounted type, "F" stands for console type, “U” stands for
outdoor of split unit
Max. 1 to 3
1.2 Brief Introduction for T1,T2,T3 working condition
1.3 Operating Range of Air Conditioners
Working temperature range
Rated
Maximum
Minimum
Indoor
DB
℃
27 32 18
WB
℃
19 23 14
outdoor
DB
℃
35 43 -10
Cooling
WB
℃
24 26 6
Indoor
DB
℃
20 27 15
WB
℃
14.5 --
--
outdoor
DB
℃
7 24 -15
Heating
WB
℃
6 18 --
Climate type
Type of Air
Conditioner
T1 T2 T3
Cooling Only
18
℃
~43
℃
10
℃
~35
℃
21
℃
~52
℃
Heat pump
-7
℃
~43
℃
-7
℃
~35
℃
-7
℃
~52
℃
Electricity Heating
~43
℃
~35
℃
~52
℃